Arming using PS1 or keyswitch
(Address 086, key [2] and key [3])
The PS1 bedside remote arming module or keyswitch can be used to stay arm, full arm, or disarm the
system. The PS1 keyswitch is enabled at address 086, key [3].
Key [2] "off": PS1 or keyswitch "regular" arms system.
Key [2] "on": PS1 or keyswitch "stay" arms system.*
*Note: If partitioning is enabled (address 086, key [8] "on"), PS1 arms system "A" only. Use of PS1 is not
recommended for partitioned systems.
Call back
(Address 086, key [4])
For extra security, the panel can be programmed to call the PC back when communication is attempted
by the PC. The panel will first answer the call, then Espload and the panel will verify identification codes.
The panel will then hang up and call the PC back and establish communication. Espload automatically
goes into the “wait for call mode”, ready to answer when the panel calls back. The identification codes
are verified again before allowing access to the panel.
Related features: “Computer telephone number” 008-015.
Auto arm
On Time:
(Address 086, key [5])
The panel may be programmed to arm at the same time every day. Program both the hour and minute
(addresses 044, 045) for arming. A late closing code may be programmed (address 516).
Related features:
“
Auto arm” 090, [2]
“Auto/Espload Arm” 300
"Auto arming" p.15.
No Movement:
(Address 086, key [6])
If zone activity is not detected for a programmed period (address 055) while disarmed, the panel can auto
arm and/or send a "no movement" report (address 517). Refer also to "No movement" p. 15.
Touch tone options
(Address 086, key [7])
Tone (key [7] = "on") or pulse dialing can be programmed. If "pulse" is chosen for a central station phone
number, "tone" dialing can be programmed for the other number. [
BYP
] ("switch from pulse to tone")
should be entered in the second phone number during programming.
Partitioning
(Address 086, key [8])
Partitioning is activated, (key [8] "on"). The panel's fully programmable zones (plus 2 remote keypad
zones) can be divided into two systems. (See “System Partitioning”, page 25.)
Silent alarm
(Address 086, key [9])
Key [9] "off":
Silent zones/panics generate a silent alarm. Zones defined as "silent" at addresses 096-098 and keypad
panic zones will not cause an audible alarm, however, the keypad "armed" light will flash and the alarm
condition will remain until a valid user code is entered.
Key [9] "on":
Silent zones/panics generate only a report (The red keypad LED does not flash, and there is no need to
"reset" the silent alarm.)
Silent delay zones generate an entry delay beep, and a report at the end of the entry delay.
Zone restore is always reported upon zone closure.
Memory display, auto zone shutdown are always active for silent zones when enabled at address 086, key [
TRBL
].
Silent alarms can be monitored by a PGM output. (Silent flag is cleared on report or disarm.)
On split reporting, silent zones/panic are reported to Telephone #1.
Dialing pulse rates
(Address 086, key [10])
This selection reflects the ratio between “pulse” time and "quiet" time. Select Pulse Europe for a 1:2 ratio
(Key [10] = "off"), Pulse USA for 1:1.5. (Key [10] = "on")
Reporting options
Regular reporting
(Address 086, key [11] “off” and key [12] “on”)
To activate central station reporting, the feature must be enabled and all required reporting codes, except
when using “Ademco contact ID (all codes reported)”, must be assigned a value other than [2
ND
][2
ND
].
18