Streamlined Section Programming:
To begin programming:
Press [
ENTER
] + installer code + [7]. ([
ENTER
] and [2
ND
] keys will flash.)
Enter 2 digit section for programming (00 - 67). ([
ENTER
] key is "steady" and [2
ND
] key is "off".)
Enter 8 digits to program the section. Keypad will beep, to show section has been programmed.
Data is saved and the next section is made available for programming.
To select a specific section, press [
CLEAR
] or [
ENTER
]. ([
ENTER
] and [2
ND
] keys will flash.)
Enter 2 digit section (00 - 67). ([
ENTER
] key is "steady" and [2
ND
] key is "off".)
To exit programming mode, press [
CLEAR
].
Installer Code:
(Addresses 000, 001, 002)
SECTION 00
(Use only numeric keys from [1] to [10] to enter installer code. Key [10] = 0.)
The default installer code contains 6 digits. Default code for the 738 is 383838 and for the 738 EXPRESS
is 737373. (Codes can also be programmed to contain 4 digits, address 088, [9] "on".) Create a new
installer code by entering the values of 1st and 2nd digit at address 000, 3rd and 4th digit at address 001,
and 5th and 6th digit at address 002.
The installer code has access to all programming addresses, except 128-299. It does not provide access
to arming/disarming or user code programming. It can be used to modify itself.
Related features:
"Installer lock" 058
"User/access code length" 088, [9]
Panel Answer Options:
(Address 003)
SECTION 00
The first digit entered disables the “Answering Machine Override” (key [2
ND
] or key [1]), or determines
the period of time between first and second call.
The second digit entered determines the number of rings required before the panel will answer.
If [2
ND
][2
ND
] is entered, the panel will not answer. (Default value is [2
ND
] [8].)
Panel Identifier:
(Addresses 004-005)
SECTION 01
This four digit code identifies the control panel to the PC before uploading can be initiated. Each pair of
code digits has its own memory address. There is no default code. Any hexa digits from 00 - FF can be
entered. Program first 2 digits in address 004 and second 2 digits in 005.
Related features:
"Panel Answer Options" 003
"Call back" 086, [4]
PC Password:
(Addresses 006-007)
SECTION 01
This four digit download password identifies the PC to the panel, prior to beginning the programming
download process. Program the first 2 digits in address 006 and the second 2 digits in 007.
Telephone and Account Numbers
Three telephone numbers can be programmed: a PC telephone number and two central station numbers.
Each number can contain a maximum of 16 digits. Special instructions can be entered in the telephone
numbers using the following keys:
[10]
= the number "0"
[
BYP
]
= switch from pulse to tone while dialing
[11]
=
*
[
MEM
]
= pause 4 seconds
[12]
= #
[
TRBL
]
= end of number
If only one central station telephone number is available, the same telephone number must be pro-
grammed for telephone number 1 and 2. A separate "communicator reporting" format can be selected for
each central station telephone number at address 038.
12
IM738-738EX