Partial arming
Will be reported to the central if the control panel is armed while any zones are
bypassed or when the system is force armed and stay armed.
Recent close
This code is sent to the monitoring station to notify that an alarm occurred shortly after
the system was armed (during the “recent closing” delay). This feature is designed to
help prevent unneeded response from the central.
Duress
A duress code is sent to the central whenever a person enters it on a keypad. This fea-
ture is primarily intended to send a silent alert if a user is forced to disarm the system
under threat. Only user 48 can use this feature.
Log-in (Espload) Will be reported to the central once the communication between the panel and the PC is over.
Program change Will be reported to the central once programming mode is entered using the installer code.
The
Esprit 's innovative keypads take a new approach to security features and functions. Each numeral
from 1 to 12 on the keypad represents an actual zone. When the [2
ND
] key flashes, the same numerals
represent a second set of 12 zones, zones 13 to 24. When the zone light is "off", the status in the protect-
ed zone is normal. If the zone light is "on", this means the zone is open.
"
CONF
" confirmation beep: an intermittent series of beeps indicating a successful keypad entry.
"
END
/
REJ
" end/rejection beep: 1 long tone indicates that the operation was incorrectly entered on the keypad.
SYSTEM ARMING/DISARMING OPTIONS
Regular System Arming (default code 474747)
(Without partitioning - for information on partitioned system arming, see page 25-26)
The green "ready" light must be illuminated. This "ready" indicator will only illuminate if all zones are
closed. All door/window contacts must be closed, and any movement in motion detector-protected areas
must be halted. When the "ready" light illuminates, a valid access code should be entered.
Upon entry of this code, the red "armed" light will illuminate, followed by the keypad "
CONF
" beep. (If the
access code is entered incorrectly, the "
END
/
REJ
" beep will sound. If an incorrect entry is made at any time,
press [
CLEAR
] and re-enter the data.) The green "ready" light will flash for the period of the exit delay, the
[
STAY
] and [
AWAY
] keys will flash (738 only) and the red "
ARMED
" light illuminates.
Note: Keypad will beep on exit if programmed at address 088, key [12].
Force (Away) Arming
[
AWAY
] + access code
To arm the system rapidly without waiting for the "ready" light, use the "away" force arming feature. The
[
AWAY
] key should be pressed, followed by a valid access code (addresses 068, 070, 072). Once the exit
delay expires, any open zones will not be considered “activated” by the panel. Open zones will not be pro-
tected, and will not generate an alarm or prevent arming. These “away” zones will become active (and
therefore, protected) as soon as they are closed. Armed status is indicated by illumination of the [
AWAY
]
key (738 only) and the red "
ARMED
" light illuminates. A "partial arm" code will be sent if programmed.
Please note: This feature is not recommended for regular use because force arming with open zones can
reduce the efficiency of system protection.
Stay Arming
[
STAY
] + access code
When "stay arming" is activated, the security installation is "partially" armed. This means that only selected
STAY
zones are armed (addresses 116, 118), so that users can remain in the protected area. This con-
venient feature (programmed at addresses 062, 064, 066) offers individuals arming the system the choice to
leave the premises during an exit delay (without altering the "stay arm" status), or remain on the premises.
A system user returning to a protected area that is "stay" armed can re-enter and disarm, as long as a valid
access code is keyed in during the entry delay. The [
STAY
] key flashes during “stay” arming for the 738 and
stays illuminated for the 738 EXPRESS.
Double "Stay" Arming
During the “stay” arming exit delay, pressing [
STAY
] (key [11]) again will switch all “stay” zones to instant
zones (no entry delays). Full system arming cancels "double stay" arming.
24
IM738-738EX