28
•
Operating the Single Burner
GS-SB1 Single Side Burner Operator Manual
Open the LP gas cylinder compartment door to inspect the gas supply
hose before each use of the burner unit. If there is evidence of
abrasion or wear, or if the hose is cut, it must be replaced before
operating the burner unit. Refer to the LP Gas section on page 23.
Lighting the Burner unit
Prior to lighting your burner unit for the first time, verify that all of the following are complete and correct:
❒
All packaging has been removed
❒
Proper gas supply and regulator type are in place
❒
The gas connection is complete, securely tightened, and leak tested (see Leak Test on page 25)
❒
All parts and components are properly in place
❒
Manual gas shut-off valve is fully accessible
❒
The LP gas hose is clean and free of cuts, wear, abrasion, or leaks. Replace if necessary with a suitable UL,
ETL, or CSA Listed part with 3/8” internally threaded connector
IF YOU SMELL GAS:
•
Immediately shut off the gas supply to the appliance at its
source
•
Extinguish any open flames
•
Open all access doors and drawers to release any
accumulation of gas vapor
•
If a gas odor persists, keep away from your appliance and
contact your gas supplier or fire department immediately
Failure to remove the burner cover before lighting the burners, or not
waiting 15 minutes to allow gas to clear if a burner does not light, may
result in a fire or explosion causing serious bodily injury, death and/or
property damage.
Содержание GS-SB1
Страница 1: ...GS SB1 Single Side Burner Operator Manual...