26
•
Single Side Burner Assembly
GS-SB1 Single Side Burner Operator Manual
Figure 17 Leak Test Spray and Bubbles
4.
If bubbles appear and/or grow, turn the gas source OFF, remove, reconnect and tighten the
connection, and re-test
5.
To leak test the burner orifice, remove the grate and burners per the Convert to Another Gas Type
procedure on page 34
6.
Look below the burner (Figure 18) and spray the orifice with soapy water to check for bubbles
Figure 18 Burner Orifice Leak Test
7.
Make note of the location of any leaks indicated by growing bubbles and turn off the gas supply
8.
Contact a qualified gas technician to tighten any loose connections or replace any faulty parts
9.
Repeat the leak check as needed; when there are no more leaks, wipe away the soap solution
10.
Replace the burner and grate and proceed
11.
Do not use the burner unit until all leaks are resolved