EN - 84
INOXPAN S.L
7.7.4. Adjustment and Calibration remote control TOUCH RF.
A -
SYNCHRONIZATION REMOTE CONTROL (* only if necessary, it is already synchronized
):
1.
Connect the hood to the mains or turn on the hood switch, optional under filters or panel.
2.
ATTENTION!: once step 2 is completed, when connecting the hood to the electricity:
DO NOT TOUCH ANY COMMAND KEY
UNTIL AFTER 5 SECONDS
3.
After the first 5 seconds
, in the interval time between 5 and 20 seconds, with the remote control facing the hood,
press or hold the LIGHT button
on the remote control, and the lights on the hood will light up,
confirming that the process has been successfully performed.
If it takes more than 20 seconds to synchronize the control, the hood switchboard closes the reception and does
not record any code, you must repeat the process, making sure to press the key between 5 "and 20”.
B - SYNCHRONIZATION REMOTE CONTROL (* only if necessary, it is already synchronized):
The manufacturer supplies the remote control ready for use, with the codes predefined in the factory.
It is not necessary to change or sync the code, except if, due to external reasons the hood does not
work (*loss of the code due to mains fluctuations, low battery power in the remote control or unintended
operation caused by interference in the frequency by another user).
If you want generate new codes, perform the following process:
Press simultaneously and keep pressed the three keys indicated in the
illustration by arrows, until the blue LED on the remote control begins to flash,
at this moment the remote is scan of the different codes, when you release
the keys, the LED will stop flashing and record the code that was being
scanned at that moment, in this manner the control code will be different to
the original one.
Warning!
Once this process has been carried out,
the
control will not communicate with the hood,
because on
changing the code in the control, it will be different from the
one the hood had before. For it to work again, you must
resynchronise the control,
see section “A”.
If you wish to use another code, repeat the process (after establishing the
factory configuration) and the selected code will depend on the time you keep
the keys pressed.