20 Number of users that can concurrently
access the unit
The maximum number of users that can concurrently access the unit is 14, including users who receive H.264
images and users who receive JPEG images. (When “On” is selected for “Activation” of “Priority stream” on
the [System] tab of the “User mng.” page.) The number of users that can concurrently access the unit may
change according to the network environment and camera settings. Take the following into consideration.
•
When “Off” is selected for “Activation” of “Priority stream”, a maximum of 12 users can concurrently access
the unit.
•
If “Frame rate” is selected for “Transmission priority” in “H.264(1)” or “H.264(2)” on the [JPEG/H.264] tab
of the “Image/Audio” page, the number of users that can concurrently access the unit may be reduced.
•
If the setting of “Max bit rate (per client)*” is increased in “H.264(1)” or “H.264(2)” on the [JPEG/H.264] tab
of the “Image/Audio” page, the number of users that can concurrently access the unit may be reduced.
•
If the “Bandwidth control(bit rate)” on the [Network] tab of the “Network” page is restricted, the number of
users that can concurrently access the unit may be reduced.
Number of users that can
concurrently access the unit
Increase
Decrease
H.264 connections:
about 10 people
“Transmission priority” in “H.
264(1)” or “H.264(2)” on the
[JPEG/H.264] tab
Constant bit rate/
Best effort
Frame rate
Frame rate
“Max bit rate (per client)*” in “H.
264(1)” or “H.264(2)” on the
[JPEG/H.264] tab
64kbps
14336kbps *
1536kbps*
“Bandwidth control(bit rate)”
on the [Network] tab
Unlimited
64kbps
Unlimited
Note
•
When “Multicast” is selected for “Transmission type” in “H.264(1)” or “H.264(2)” on the [JPEG/H.264]
tab of the “Image/Audio” page, only the first user who accessed to monitor H.264 images will be
included in the maximum number. The second and subsequent users who monitor H.264 images will
not be included in the maximum number.
•
When “On” is selected for “Activation” of “Priority stream” on the [System] tab of the “User mng.” page,
because network bandwidth is constantly reserved for “Priority stream”, the number of users that can
concurrently access the unit may be reduced.
•
When “HTTPS” is selected for “HTTPS” - “Connection” on the [Network] tab of the “Network” page, the
number of users that can concurrently access the unit may be reduced.
202
Operating Instructions
20 Number of users that can concurrently access the unit
Содержание WV-SC588
Страница 60: ...60 Operating Instructions 10 Configure the basic settings of the camera Basic ...
Страница 182: ...8 Click Next 9 Click Finish 182 Operating Instructions 17 Configuring the network settings Network ...
Страница 208: ... When using a firewall including software allow access to all UDP ports 208 Operating Instructions 21 Using the CD ROM ...
Страница 226: ...226 Operating Instructions Notes ...
Страница 227: ...Operating Instructions 227 Notes ...