282
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
7 Installation
7.1.
Precautions During Set Up
Before you begin the installation, read these entire instructions. You must locate an appropriate site (firm
and leveled surface) for the installation. Reading this section assists you with the decision making process.
Machine performance and the copy quality is subject to and dependant on environmental conditions.
To maintain good performance, quality, and safe operation, observe the following precautions:
1. For safe operation and to avoid trouble, do not install the system under the following conditions:
• High temperature, high humidity, low temperature or low humidity
• Sudden changes in temperature or humidity
• Exposed to direct sunlight
• Dusty environment
• Poorly ventilated location
• Exposed to chemical gases (such as ammonia gas)
• Exposed to strong vibration
• Exposed to direct air current (ex. Air conditioner vent)
2. The weight of the machine (options not included) is as follows:
DP-3510/3520/3530
: 283 lb (128.5 kg) with the i-ADF pre-installed
DP-4510/4520/4530/6010/6020/6030 : 290 lb (131.5 kg) with the i-ADF pre-installed
3. The maximum power consumption is 1.5 kW. Depending on the product destination, the wall outlet
must be rated for 120 VAC or 220-240 VAC accordingly. It must also be protected for at least 15 amps
for 120 VAC, or 10 amps for 220-240 VAC. If you are in doubt about a power source, ensure that a
qualified electrician checks the outlet. Do not connect any other devices to the wall outlet designated
for this machine. (Do not use an extension cord)
4. Make sure the outlet is properly grounded. (Do not ground to gas or water pipe)
5. This machine has ventilation openings on the side and rear, which must remain unobstructed for safe
operation. The machine should be located at least 3.9 inches (100 mm) from the wall. Obstructing the
ventilation openings could present a fire hazard.
Using the space requirements shown on page 2, ensures that the machine has the ventilation it
requires and that you have the space needed for replacing the supplies.
Содержание Workio DP-3510
Страница 4: ...4 Beispiel DP 6530 4530 6030 Hinweis...
Страница 423: ...423 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 8 35 Installing the Stand DA D351 D352...
Страница 424: ...424 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 425: ...425 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 474: ...474 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 memo...
Страница 807: ...807 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 2 Motor PCBs Fig 5 009 M1 M2 M8 M5 M4 M3 M7 M6 1...
Страница 827: ...DZSD001829 11 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3...
Страница 842: ...memo...
Страница 843: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3...
Страница 854: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next...
Страница 858: ...DZZSM00298...