![Panasonic Workio DP-3510 Скачать руководство пользователя страница 191](http://html1.mh-extra.com/html/panasonic/workio-dp-3510/workio-dp-3510_service-manual_3495509191.webp)
191
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
4.6.
Information Codes Table (For Facsimile)
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
012
RCV
C, D
The length of the received
document is over 2 m.
Transmitter Document Jam.
030
XMT
B
Read Point Sensor does not
activate within 10 seconds after
the document starts feeding.
Document is not set properly.
Defective Read Point Sensor.
031
XMT
COPY
C
Transmitting document was longer
than 2,000 mm (or 78.7 in).
(Super Fine: 1,000 mm (or 39.4
in), 600 dpi: 430 mm (or 16.2 in))
The document may jam.
Defective Read Point Sensor.
061
-
A
ADF Door is open.
Cover is not firmly closed.
Connectors are not firmly connected.
200
RCV
C
Decoding process is not
completed at the end of phase C.
Defective FXB PCB.
212
XMT
RCV
A-E
Interface error occurred between
the CPU and modem.
Modem is defective. (FXB PCB)
Software problem occurred. (SC PCB)
301
XMT
RCV
System fault.
Software problem occurred. (SC PCB)
331
XMT
C
8-minutes timer error.
(Germany only)
400
XMT
B
T1 timer (35±5 sec) elapsed
without detecting 300 bps signal.
Wrong number is dialed and the START
button is pushed.
Telephone line is disconnected while
dialing.
FXB PCB (Modem) or MJR PCB is
defective.
Receiver is defective. (It may only be
transmitting CED)
401
XMT
B
DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
Your machine's ID Number is not
programmed.
Possible incompatibility or incorrect
Password (Password Reception,
Selective Receive).
Mailbox is full.
402
XMT
B
DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
Receiver working in non-CCITT mode
only. (Possible incompatibility)
403
RCV
(Polling)
B
Transmitter had no polling
function.
"POLLED=ON" (polling XMT ready) is
not set at the transmitter.
Document to be transmitted is not
placed at the transmitter.
404
XMT
B
Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Receiver is defective. (Modem, MJR
PCB, etc.)
FXB PCB or MJR PCB is defective.
Receiver disconnects line during first
NSS (or DCS) is transmitted.
Содержание Workio DP-3510
Страница 4: ...4 Beispiel DP 6530 4530 6030 Hinweis...
Страница 423: ...423 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 8 35 Installing the Stand DA D351 D352...
Страница 424: ...424 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 425: ...425 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 474: ...474 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 memo...
Страница 807: ...807 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 2 Motor PCBs Fig 5 009 M1 M2 M8 M5 M4 M3 M7 M6 1...
Страница 827: ...DZSD001829 11 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3...
Страница 842: ...memo...
Страница 843: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3...
Страница 854: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next...
Страница 858: ...DZZSM00298...