6. If the gap is less than 5 mm, input a (+) value. If more than 5 mm, input a (-) value.
7. Press "STOP" key first and then press "FUNCTION" + "CLEAR" keys simultaneously to return to
standby.
3.9.
QUANTUM Control in F8-14
To stabilize the initial print quality, the contents of the F8-14 function was changed beginning from June '02
production. (Starting with Serial No. FBG2Kxxxxxx)
1. Description of the Change
2. Field Installation Procedure
* For New machines, use the following procedures at installation.
* For Machines already set up, use the following procedures during PM
1. Make sure that the LAN cable is disconnected before performing F8-09
2. Make sure that paper is set in any paper tray before performing F8-09
3. After performing F8-14, please use the additional procedure manually for all machines
which were produced from Feb ’02 to May ’02 production.
(Serial No. range from BBG2Kxxxxxx to EBG2Kxxxxxx)
.
3. QUANTUM Control Timing
Refer to the following Table.
.
Toner Density Sensor
Output Gain Adj.
Self-Adjusting
(QUANTUM) 1min
Ready
Go to Image
Quality Adj.
F8-14 Contents
Toner Density Sensor
Output Gain Adj.
Ready
Go to Image
Quality Adj.
F8-14 Contents
Current
New
Proceed to
F8-14
Turn Power
Switch OFF/ON
Ready
Wait approx.
90 sec.
Ready
Self-Adjusting
(QUANTUM) 1 min
Ready
Go to Image
Quality Adj.
Additional Procedure
Содержание Workio DP-3510
Страница 4: ...4 Beispiel DP 6530 4530 6030 Hinweis...
Страница 423: ...423 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 8 35 Installing the Stand DA D351 D352...
Страница 424: ...424 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 425: ...425 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030...
Страница 474: ...474 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 memo...
Страница 807: ...807 JAN 2006 Ver 5 2 DP 3510 3520 3530 4510 4520 4530 6010 6020 6030 2 Motor PCBs Fig 5 009 M1 M2 M8 M5 M4 M3 M7 M6 1...
Страница 827: ...DZSD001829 11 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3...
Страница 842: ...memo...
Страница 843: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3...
Страница 854: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next...
Страница 858: ...DZZSM00298...