background image

Before attempting to connect or operate this product,

please read these instructions carefully and save this manual for future use.

WJ-HD309A

Model Nos.

WJ-HD316A

Digital Disk Recorders

Operating Instructions

+

TIMER

ERROR

ALARM
RESET

HDD 1

HDD 2

PULL

ALARM

ALARM

SUSPEND

OPERATE

Digital Disk Recorder

WJ-HD 

316

A

MONITOR1
MONITOR2

SHIFT

DISK SELECT

EL-ZOOM

COPY

TEXT

MARK

PAN/
TILT

ZOOM/
FOCUS

IRIS

LISTED

BUSY

A-B

REPEAT

PAN/TILT

SLOW

SETUP

/ESC

SEARCH

REV

FWD

SET

GOTO
LAST

PRESET
/AUTO

LOGOUT

OSD

SEQ

1

4

7

8

9

11

12

13

14

15

16

10/0

5

2

6

3

-  REC STOP

REC-

STOP

PAUSE

PLAY

Содержание WJHD309A - DIGITAL DISK RECORDER

Страница 1: ...s Operating Instructions TIMER ERROR ALARM RESET HDD 1 HDD 2 PULL ALARM ALARM SUSPEND OPERATE Digital Disk Recorder WJ HD 316A MONITOR1 MONITOR2 SHIFT DISKSELECT EL ZOOM COPY TEXT MARK PAN TILT ZOOM FOCUS IRIS LISTED BUSY A B REPEAT PAN TILT SLOW SETUP ESC SEARCH REV FWD SET GOTO LAST PRESET AUTO LOGOUT OSD SEQ 1 4 7 8 9 11 12 13 14 15 16 10 0 5 2 6 3 REC STOP REC STOP PAUSE PLAY ...

Страница 2: ...s or modifications not expressly approved by the party responsible for compli ance could void the user s authority to operate this equip ment For U S A WARNING To prevent fire or electric shock hazard do not expose this appliance to rain or moisture The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus The...

Страница 3: ... OR NEGLIGENT OPERATION OF THE USER 3 UNAUTHORIZED DISASSEMBLE REPAIR OR MODIFI CATION OF THE PRODUCT BY THE USER 4 ANY PROBLEM CONSEQUENTIAL INCONVENIENCE OR LOSS OR DAMAGE ARISING OUT OF THE SYS TEM COMBINED BY THE DEVICES OF THIRD PARTY 5 ANY CLAIM OR ACTION FOR DAMAGES BROUGHT BY ANY PERSON OR ORGANIZATION BEING A PHO TOGENIC SUBJECT DUE TO VIOLATION OF PRIVACY WITH THE RESULT OF THAT SURVEILL...

Страница 4: ...t an electrician for replacement of the obsolete outlet 10 Protect the power cord from being stepped on or pinched particularly at plugs convenient receptacles and the points where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart...

Страница 5: ...on labels placed on the top and bot tom of the unit as to the indications of equipment classi fication and power source etc Built in hard disk drives Hard disk drives are vulnerable to vibration Handle them with care It is possible to damage them if they are moved while their motors are still running Do not move them just after turning their power on or off for around 30 sec onds When hard disk dr...

Страница 6: ...tions Network Operating Instructions PDF Network Setup Instructions PDF These Operating Instructions contain descriptions of how to operate this unit with the buttons on the front panel Refer to the Network Operating Instructions on the provid ed CD ROM for descriptions of how to operate this unit from a PC Refer to the Network Setup Instructions on the provided CD ROM for descriptions of how to p...

Страница 7: ...he front panel 64 Setup 64 Operation using the system controllers 65 MANAGEMENT OF USERS HOSTS 66 OPERATING THE UNIT FOR THE FIRST TIME 68 Preparation for maintenance HDD replacement installation etc 69 INSTALLATIONS 71 Places to avoid 71 Rack mounting 71 CONNECTIONS 72 Connections when the unit is used independently 73 Connections with an extension unit 74 Connections with DVD RAM CD R and DVD R ...

Страница 8: ... mode quality and recording rate can be changed to high quality to record pictures Motion Detection Function VMD It is possible to start recording automatically when motion is detected in a shooting area Frame Switcher Function It is possible to display pictures of four or more cam eras on a single monitor multi screen splitting the monitor screen into 4 7 9 10 13 or 16 sections using the WJ HD316...

Страница 9: ...dicator off press the ALARM RESET but ton r Alarm Reset Button ALARM RESET Pressing this button cancels alarm activation and returns the system to the condition before the alarm was activated t Error indicator ERROR Blinks orange when an error occurs that will not keep the unit from running Blinks red when an error occurs that may cause the system to go down Refer to page 60 for further informatio...

Страница 10: ... menu 3 Set Button SET Works differently depending on the situations listed below Plays recorded images at the current playback speed when this button is pressed during fast play back Registers preset positions of cameras Activates the auto focus function Resets the set iris Sets the alarm suspension mode on off Determines the setting of parameters on the setup menus 4 Jog Dial Works differently d...

Страница 11: ...WER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 1 8 w t y ui o 0 1 3 5 8 2 4 6 7 e r...

Страница 12: ...pper right lower left lower right center The default camera title position is upper right R UPPER Note The camera title will be displayed with 16 charac ters 2 lines 8 characters per line 2 Time Displays the current time hour minute second and date month day year A position to display the time can be selected from the following Upper left lower left upper right lower right The default time display...

Страница 13: ...setting SIF a part of the embedded camera title may not be displayed Important Since the VGA output from this unit is the same as for televisions 720 H x 480 V pixels vertical frequency of 59 94 Hz it may be possible that both the left and right edges can not fit onto the screen depending on the VGA monitor It is impossible to use the MONITOR VGA connector when connecting the unit in the cascade c...

Страница 14: ...e image display status Indicates that playback is currently being performed with the displayed playback speed Live image is displayed Live images are displayed sequentially 5 Currently playing 4 Currently playing in reverse h Currently pausing 2 Currently playing at fast speed 1 Currently playing in reverse at fast speed Indicates that recording is currently being performed Currently recording Cur...

Страница 15: ... n Number of connector that an external recording device is connected to Abbreviation of partition Status Displayed abbreviation Normal recording area NML Event recording area EVT Copy area CPY External recording device connected to the COPY1 port on the rear panel CP1 External recording device connected to the COPY2 port on the front panel CP2 Notes Refer to page 60 for further information about ...

Страница 16: ...ormation NML Available disk space of the normal record ing area used for manual recording and schedule recording EVT Available disk space of the event recording area used for event recording and emergency recording Indicated Item Camera Indicates recording and displaying status Gray Camera currently not displayed or not con nected to the respective channel Green Camera displayed on the monitor Ora...

Страница 17: ...enu by pressing the SET button when the image shown below that says the system check has been completed is dis played Important The startup splash window will not be displayed on monitor 1 c Enter a user name and password Rotate the jog dial to select a character to be entered in the cursor position It is also possible to enter numbers by pressing the camera selection buttons 1 10 0 for the WJ HD3...

Страница 18: ...EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUSY 316 REV FWD STOP PLAY PAUSE REC REC STOP SEARCH SETUP ESC PAN TILT SLOW A B REPEAT GOTO LAST LISTED PAN TILT ZOOM FOCUS IRIS PRESET AUTO SET zv c x xc SETUP MENU LIVE Quick Display REC Event Network Advanced Menu Date Format Time Format Time Date Time Date Display Position Camera Title Camera Title Display Position Live Sequence Summer Time Day Ligh...

Страница 19: ...OP button Playback will stop and the indicator on the PLAY PAUSE button will go off Turn off the power of the unit after confirming that the HDD1 and HDD2 indicators are off Important Detach the plug from the outlet if not operating the unit for a length of time When the unit has not been used for a certain period turn on the power of the unit approximately once a week and perform recording playba...

Страница 20: ...n to start recording The indicator on the button will light and recording will start Images from all the connected cameras will be recorded with the default setting It is possible to record only images displayed on monitor 2 and the VGA monitor by changing the settings R 2 R 1 LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 B...

Страница 21: ...dicate which camera is being recorded When starting emergency recording while another recording with a different recording mode except event recording is being performed the indicator on the REC button will remain lit and the other recording will resume after the emergency recording has finished Recording duration of emergency recording Recording duration of emergency recording can be set as follo...

Страница 22: ...playback Press the STOP button The indicator on the PLAY PAUSE button will go off and playback will be stopped Live images will be displayed on monitor 2 and the VGA monitor PLAYBACK R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 0 14 3 7 11 15 4 8 12 16 SEQ SHIFT OSD STOP PLAY PAUSE REC REC STOP ZOOM FOCUS TEXT COPY DISKSELECT EL ZOOM MARK LOGOUT IRIS PRESET AUTO A B REPEAT GOTO LAST LISTED SEARCH BUSY ...

Страница 23: ...will skip to the start time of the previous recording If there is no next or previous recorded image current playback will continue Play the latest recorded image Press the GO TO LAST button to play the latest recorded image When the GO TO LAST button is pressed for 2 seconds or more while displaying live images playback of the latest recorded images will start When the GO TO LAST button is presse...

Страница 24: ...ime of point A will be dis played To cancel the designated point press the SETUP ESC button w Designate an end point B by pressing the A B REPEAT button during playback When the start point and the end point are set the A B REPEAT indicator will start blinking Playback between point A and B will start and keep playing repeatedly The time of point A and B will be displayed during playback e Press t...

Страница 25: ... 2 port of the unit Recorded images will be copied in this area To search for a recorded image and play it when COPY 1 or COPY 2 is selected as the recording area Search for copy data and play it back Copy Data Search page 32 Notes Playback images will be displayed only on monitor 2 and the VGA monitor Playback can be performed during recording When a pre recording area is created in an optional e...

Страница 26: ...corded at a high recording rate n To stop playback press the STOP button The indicator on the PLAY PAUSE button will go off and playback will stop Live images will be displayed on monitor 2 and the VGA monitor Note Pressing the PLAY PAUSE button after stopping play back will start playback from the end point of the recorded image played last time R 2 R 1 LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13...

Страница 27: ...e PLAY PAUSE button will light and start playback from the entered time and date If there is no recorded image after the entered time When there are images recorded after the entered time the oldest recorded image after the entered time will be played When there are no images recorded after the entered time the newest recorded image before the entered time will be played v Press the STOP button Th...

Страница 28: ...ed in the entered time range CAMERA Search for only recorded images from the selected camera channel REC EVENT Search for only images recorded in the selected recording mode It is possible to search for images recorded in the following recording modes EMERGENCY Emergency recording Refer to page 21 VMD Event recording performed when motion was detected TERMINAL Event recording performed when a term...

Страница 29: ...e currently displayed list will be dis played in orange Recording Event Thumbnail Window Time and date Camera channel Recording event Number of the listed data Time and date When searched by recording event The time when recording started will be displayed When searched by VMD The time when motion was detected will be displayed When searched by marked point The time when the point was marked will ...

Страница 30: ... 01ch 01ch 01ch 01ch MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL CAM REC EVT ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ TEXT AUG 20 04 3 04 23 PM AUG 20 04 3 01 24 PM AUG 20 04 3 00 40 PM AUG 20 04 3 00 00 PM AUG 20 04 2 59 11 PM AUG 20 04 2 45 45 PM AUG 20 04 2 44 09 PM AUG 20 04 2 33 16 PM TIME DATE SEARCH REC EVENT SEARCH VMD SEARCH MARK ...

Страница 31: ...8 using the arrows button C D and rotate the jog dial to ON Press the SET button to determine the selection The recording events of the selected filter will be listed Filter recording events by text information Rotate the jog dial to select OFF WITH TEXT or WITHOUT TEXT Press the SET button to determine the selection The recording events filtered by the selected filter will be listed v Rotate the ...

Страница 32: ... Data List Window Important In the recording event list the start time of recording will be displayed When events occurred successively the contents of the event log and the recording event list will not always match since the unit continues to record the first occur ring event TIME DATE 01ch 01ch 01ch 01ch 01ch 01ch 01ch 01ch MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL CAM REC EVT ABC...

Страница 33: ...e searched time and date the displayed time and date on the list thumbnail window may not matchthe start time of the recorded images to be played If the copy completion is not performed for the CD R DVD R disk it is impossible to search play copied recorded images on the CD R DVD R disk Refer to page 53 for further information about the copy completion When the clock of the unit has been changed b...

Страница 34: ... 04 3 00 00 PM AUG 19 04 2 29 00 PM COPY DATA TIME DATE CAMERA REC EVENT TEXT UNLOCK FILTER TOTAL TIME DATE 01ch 01ch MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL CAM REC EVT ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ ABCDEFGHIJ TEXT AUG 20 04 3 00 00 PM AUG 19 04 2 29 00 PM COPY DATA TIME DATE CAMERA REC EVENT TEXT UNLOCK FILTER TOTAL x Use the arrows ...

Страница 35: ...R2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUSY 316 REV FWD STOP PLAY PAUSE REC REC STOP SEARCH SETUP ESC PAN TILT SLOW A B REPEAT GOTO LAST LISTED ZOOM FOCUS IRIS PRESET AUTO SET b c v n c c c PAN TILT START JAN 1 04 SET SET CANCEL ESC 12 00 TIME DATE FILTERING AM END JAN 1 04 12 00 AM v Rotate the jog dial to select the recording event to b...

Страница 36: ...indow is of the results of the pre vious search Use the arrows button C D to switch between displaying the list window and the thumbnail window alternately List window R 2 R LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUSY 316 REV FWD STOP PLAY PAUSE REC REC STOP SEARCH SETUP ESC PAN TILT SLOW A B REPEAT GOTO LAST LISTED ...

Страница 37: ... time range set in step 3 the motion detection area setup window will not be displayed when the SET button is pressed b Rotate the jog dial to select SETUP AREA on the status bar Note It is possible to set all displayed areas as motion detection areas by pressing the SET button after select ing ALL AREAS n Move the cross cursor using the arrows button to a point to be determined as the start point...

Страница 38: ...point to be determined as the end point of the motion detection area Press the SET button to determine the selected point as the end point of the motion detection area It is possible to set up to 4 motion detection areas by repeating steps 6 and 7 Press the SET button after selecting SENSI TIVITY by rotating the jog dial Notes Depending on the set positions of the detection areas the sensitivity i...

Страница 39: ... the search results are dis played It is possible to stop searching by pressing the STOP button 6 Rotate the jog dial to select a result to be dis played It is possible to turn the page by rotating the shuttle ring 7 Press the PLAY PAUSE button to start play back The LISTED indicator and the indicator on the PLAY PAUSE button will light and playback of the selected recording will start Note It is ...

Страница 40: ... sec for area D An event action will be performed when an object keeps moving longer than the set period in the specified detection area Important When images to be searched are recorded with a low recording rate the DURATION mode may not work cor rectly It may take some time to search according to the con tents of the recorded images To delete the motion detection area z Rotate the jog dial to se...

Страница 41: ...corded images with marked points may have been deleted by overwrite recording or the delete function v Press the STOP button The indicator on the PLAY PAUSE button will go off and playback will be stopped Live images will be displayed on monitor 2 and the VGA monitor R 2 R 1 LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUS...

Страница 42: ...nic Zoom When displaying a single screen zooming in on the dis played image is possible Electronic zoom is available only on the selected monitor When the MONITOR1 MONITOR2 indicator is lit the moni tor 1 is selected electronic zoom works only on monitor 1 z Press the SHIFT button when monitoring live images on a single screen The SHIFT indicator will light R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 ...

Страница 43: ...ction button 4 16 split screen Only for the WJ HD316A Camera selection button 5 10 split screen Only for the WJ HD316A Camera selection button 6 13 split screen Only for the WJ HD316A The camera selection buttons respective to the live images displayed on a multi screen will light green or blue When monitor 2 is selected in step 1 live images will also be displayed on the selected multi screen on ...

Страница 44: ...plied Auto skip function Refer to a system administrator for further information Cameras that are out of the controllable range set by the camera partitioning function will be skipped Refer to the Network Setup Instructions PDF for further infor mation about the camera partitioning R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 0 14 3 7 11 15 4 8 12 16 SEQ SHIFT OSD STOP PLAY PAUSE REC REC STOP ZOOM FOCU...

Страница 45: ...ng Zooms in out on images Depending on models of the con nected cameras the image size for the respective zooming level may be different For further information refer to the operating instruction for the camera z Press the ZOOM FOCUS button The ZOOM FOCUS indicator will light x Use the arrows button CD to zoom in on or out of the displayed image Press the arrows button downward C to zoom out and u...

Страница 46: ...ions and move a camera to a preset position by performing the following steps In this case perform the settings using the setup menu of camera Register Preset Positions of Cameras Up to 256 preset positions can be registered z Press the PAN TILT button and move the cam era to a desired position to be registered as a preset position x Press the SET button The REGISTRATION PRESET POSITION window wil...

Страница 47: ...n the monitor will be registered as a preset position with the selected preset position number To cancel the selected preset position select CANCEL using the arrows button and press the SET button The set ting will be canceled and the REGISTRATION PRESET POSITION window will be closed R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 0 14 3 7 11 15 4 8 12 16 SEQ SHIFT OSD STOP PLAY PAUSE REC REC STOP ZOOM F...

Страница 48: ...OK using the arrows button and press the SET button The PRESET AUTO PAN window will be closed and auto function will start During auto function it is impossible to register a preset position To close the PRESET AUTO PAN window select CANCEL using the arrows button and press the SET but ton The setting will be canceled and the PRESET AUTO PAN window will be closed Note Refer to the operating instru...

Страница 49: ...formed according to the set tings when an event occurs There are 2 event action modes the alarm mode ALARM and the activity detection mode ACT DET for each event type The event action will be different according to the event action mode set When an event of the alarm mode ALARM occurs this unit activates the alarm action About the event action mode Alarm Mode ALARM This mode announces an event occ...

Страница 50: ...ce Alarm Output Sends a signal to the device connected to the ALARM CONTROL connector and the connected device such as a buzzer will be activated Starts recording automatically Starts recording the image from the location of the event occurrence automatically Moves a camera to the preset position A camera will move to the preset position registered in advance Announces an event occurrence by sendi...

Страница 51: ...s are suspended To suspend deactivate temporarily the alarm actions z Press both the ALARM RESET button and the SET button at the same time The ALARM SUSPEND indicator will light To stop suspending the alarm actions x Press both the ALARM RESET button and the SET button at the same time again The ALARM SUSPEND indicator will go off Note When an external switch is connected to the ALARM CONTROL con...

Страница 52: ...the unit has been changed by editing the time and date settings or by the auto time adjust ment function overlapping of the time ranges of the images recorded before and after the time adjustment could occur In this case copying may not function properly z Press the SHIFT button The SHIFT indicator will light To copy recorded images during playback pause the play back temporarily x Press the COPY ...

Страница 53: ...e closed In the following cases copying will not start even when you move the cursor to OK and press the SET button When another user has selected the desired copy drive When copying is being performed manually Important To eject the disk do the following operation copy com pletion while live images are displayed before pressing the eject button of the external recording device Copy icon R 2 R 1 L...

Страница 54: ...EC STOP SEARCH SETUP ESC PAN TILT SLOW A B REPEAT GOTO LAST LISTED ZOOM FOCUS IRIS PRESET AUTO SET z xc xcv PAN TILT Event Schedule System Display Comm Switcher SETUP MENU LIVE Maintenance Recording REC Rate Disk Info Version Info Disk End Mode Disk Capacity Data Delete Event Log Error Log Access Log Quick Menu Auto Delete Manual Delete for Normal Recording Area Delete before JAN 1 04 Manual Delet...

Страница 55: ...Y2 Front DELETE FORMAT FORMAT OFF DELETE Advanced Event Schedule Display Comm Switcher SETUP MENU LIVE Recording System Maintenance REC Rate Disk Info Version Info Disk End Mode Disk Capacity Data Delete Event Log Error Log Access Log Quick Menu Auto Delete Manual Delete for Normal Recording Area Delete before JAN 1 04 Manual Delete for Event Recording Area Delete before JAN 1 04 Disc Format of DV...

Страница 56: ...ccess Log Quick Menu Auto Delete Manual Delete for Normal Recording Area Delete before JAN 1 04 Manual Delete for Event Recording Area Delete before JAN 1 04 Disc Format of DVD COPY1 Rear COPY2 Front DELETE FORMAT FORMAT OFF DELETE Advanced FORMAT FORMAT DELETE Event Schedule Display Comm Switcher SETUP MENU LIVE Recording System Maintenance REC Rate Disk Info Version Info Disk End Mode Disk Capac...

Страница 57: ...tomatically after com pleting formatting Press the SETUP ESC button for 2 seconds or more to close the SETUP MENU Advanced Live images will be displayed on monitor 2 and the VGA monitor OK CANCEL All of data in the COPY1 is going to be erased Starting format R 2 R 1 LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUSY 316 REV...

Страница 58: ... TEXT button again to edit text infor mation R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 0 14 3 7 11 15 4 8 12 16 SEQ SHIFT OSD STOP PLAY PAUSE REC REC STOP ZOOM FOCUS TEXT COPY DISKSELECT EL ZOOM MARK LOGOUT IRIS PRESET AUTO A B REPEAT GOTO LAST LISTED SEARCH BUSY SETUP ESC SET REV FWD PAN TILT SLOW WJ HD316A LOGOUT R 2 R MONITOR1 MONITOR2 1 4 7 2 5 8 0 3 6 9 TEXT SEQ SHIFT OSD ZOOM FOCUS COPY DISKSE...

Страница 59: ...text n Press the SET button to apply the edited char acters To cancel the edit press the SETUP ESC button The edit ed characters will not be applied Important It is impossible to edit text information using the system controller TEXT INFORMATION EDIT TEXT SET SET CANCEL ESC Digital Disc Recorder WJ HD316 R 2 R MONITOR1 MONITOR2 1 5 9 13 2 6 10 0 14 3 7 11 15 4 8 12 16 SEQ SHIFT OSD STOP PLAY PAUSE...

Страница 60: ...r will light steadily Error half reset If the error is eliminated the ERROR indicator will go off when the ALARM RESET button is pressed while the ERROR indi cator is lit Error reset Status Description Solution Error Warning Warning Recorded image has been altered Playback will be paused Failed to write data on the HDD The hard disk may be malfunctioning and may not work correctly The set time for...

Страница 61: ...ondition Consult the dealer Press the ALARM RESET button to can cel the error status The unit will be in the error half reset condition Contact the dealer MEDIUM n REMOVE FAN HDD ERROR Warning Error Warning Error Press the ALARM RESET button to can cel the warning status The unit will be in the error half reset error reset condition Confirm that a disk has been inserted or check the inserted disk ...

Страница 62: ...15 nn Available disk space percentage n COPY port number to which an external recording device is connected Note The available disk space warning will be given only once when the available disk space has reached the set value Mail notification of an available disk space warning will be sent each time 1 of the available disk space is reduced after the available disk space has reached the set value ...

Страница 63: ...also possible to send an e mail with a recorded image of the place where the event occurred Host authentication It is possible to restrict devices from operating this unit if their IP addresses are not registered System Requirements of a PC It is recommended to operate this unit using a PC that meets the following system requirements If using a PC that does not meet the following system requiremen...

Страница 64: ... PLAY PAUSE REC REC STOP ZOOM FOCUS TEXT COPY DISKSELECT EL ZOOM MARK LOGOUT IRIS PRESET AUTO A B REPEAT GOTO LAST LISTED SEARCH BUSY SETUP ESC SET REV FWD PULL Digital Disk Recorder WJ HD A PAN TILT SLOW First unit Unit Address System 001 Second unit Unit Address System 002 Third unit Unit Address System 003 System Controller Unit Address 002 Fourth unit Unit Address System 004 System Controller ...

Страница 65: ...ill be displayed on monitor 1 connected to the unit currently in use Refer to the operating instructions of the system controller for further information about the PS Data mode operation 1 When the WV CU360C is used for the unit address 001 images from the desired camera channel sometimes may not be displayed on monitor 2 connected to the first unit In this case select the desired camera chan nel ...

Страница 66: ... logged in this user can log in and the other user who has already logged in will be forced to log out When a user s priority is lower than the one of the other user who has already logged in this user cannot log in When another user has already logged in any user except administrators cannot log in regardless of priority When an administrator has logged in the other user who has already logged in...

Страница 67: ...Setup 1 Setting for Priority Follow the priority Pre priority Post priority When a host s priority is higher than the one of the other host who has already logged in this host can log in and the other host who has already logged in will be forced to log out When a host s priority is lower than the one of the other host who has already logged in this host cannot log in Any host cannot log in regard...

Страница 68: ...IN Password 12345 To enhance the security change the password for an administrator periodically v Press the SETUP ESC button for 2 seconds or more The SETUP MENU Quick will be displayed Adjust the clock of the unit with this menu Refer to page 18 for further information about clock adjust ment b With the default setting the unit is ready to start manual recording Perform the settings for recording...

Страница 69: ...GB 160GB 15000h 15000h EXT6 160GB 160GB 15000h 15000h EXT7 Warning for Disk Life Time HDD Safety Mode 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h 160GB 160GB 15000h 15000h Normal REC Area Event REC Area Copy Area COPY 1 Rear COPY 2 Front 3000h OFF Remaining 1 2 ...

Страница 70: ...nfirming that the OPERATE indicator on the front panel is not lit Otherwise it may cause malfunction When replacing the built in hard disk of the unit Move the cursor to REMOVE using the arrows button and press the SET button The OPERATE indicator on the front panel will go off The power supply to the front panel will be cut and the unit will be unable to operate with the front panel Detach the ca...

Страница 71: ...ix the unit firmly with the rack mounting screws 4 pcs Important The cooling fan inside the unit is perishable and must be replaced periodically Do not block the ventilation openings or slots in the cover to prevent the unit from overheating If the rack is subject to vibration secure the rear of the unit to the rack using additional mounting brackets not included Be sure to keep the temperature in...

Страница 72: ...it to this unit the looped through output signal for every video input signal from them must be supplied to the video input connectors of this unit directly Do not supply the monitor output signal or the spot output signal from the matrix switcher or the data multiplex unit to the video input connectors of this unit Otherwise the images may be disorderly displayed and recorded for a split second T...

Страница 73: ...on cameras connect them to the video input connectors 1 8 when using the WJ HD316A or 1 6 when using the WJ HD309A for coaxial communication Examples of connections Notes The SETUP MENU will be displayed on monitor 2 and the VGA monitor It is impossible to display the SETUP MENU on monitor 1 The same images displayed on monitor 2 will be displayed on the VGA monitor Microphone Note If the DATA and...

Страница 74: ...n unstable system 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 This unit Cable attached to the extension unit Extension unit WJ HDE300 series POWER AC IN SIGNAL GN...

Страница 75: ... HDD 1 ALARM SUSPEND OPERATE LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKSELECT EL ZOOM TEXT LOGOUT 4 8 12 OSD MARK 1 15 16 BUSY REV FWD STOP PLAY PAUSE REC REC STOP SEARCH SETUP ESC PAN TILT SLOW A B REPEAT GOTO LAST LISTED ZOOM FOCUS IRIS PRESET AUTO SET ALARM RESET S VIDEO COPY 2 VIDEO OUT AUDIO OUT PAN TILT 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 1...

Страница 76: ...nt panel When connecting multiple units in the cascade connection it is impossible to supply video output signals of an other unit using the S VIDEO connector or the MONITOR VGA connector Connect VCRs individually to each WJ HD316A WJ HD309A unit VCR Open the connectors cover ALARM TIMER HDD 2 ERROR HDD 1 ALARM SUSPEND OPERATE LOGOUT MONITOR1 MONITOR2 5 9 2 6 10 0 14 13 3 7 11 SHIFT SEQ COPY DISKS...

Страница 77: ...compatible device it is necessary to set each item of PS Data Setup of Comm on the SETUP MENU according to the system configuration The PS Data is our exclusive protocol Contact the dealer about devices that can be connected When connecting this unit with a controller System Controller Controller Termination ON Unit Address 1 RS485 cable provided with the controller Mode switch No 7 ON No 8 OFF PS...

Страница 78: ...N PS Data setup of Comm on the SETUP MENU Unit Address System 1 Unit Address Controller 2 No 7 OFF No 8 ON POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND 1 2 3 4 ESC SET RESET SUSPEND SET UP ALARM UNIT 0 9 8 7 6 5 4 3 2 1 POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND 1 2 3 4 ESC SET RESET SUSPEND SET UP ALARM UNIT 0 9 8 7 6 5 4 3 2 1 RS485 cable RS485 cable Mode swit...

Страница 79: ... Setup of Comm on the SETUP MENU RS485 Cable BNC Cable Locally procured BNC Cable Locally procured BNC Cable Locally procured RS485 Cable No 7 ON No 8 OFF 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS48...

Страница 80: ...2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 No 7 ON No 8 OFF No 7 OFF No 8 OFF System Controller First unit this unit System 1 Controller 2 Second unit System 2 Control...

Страница 81: ... 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 No 7 OFF No 8 OFF No 7 OFF No 8 OFF First unit this unit System 1 Controller 1 Second unit System 2 Controller 2 Third unit System 3 Controller 3 Monitor 2 Mode switch No 7 O...

Страница 82: ...1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 No 7 OFF No 8 OFF No 7 OFF No 8 OFF POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND 1 2 3 4 ESC SET RESET SUSPEND SET UP ALARM UNIT 0 9 8 7 6 5 4 3 2 1 First unit this unit System 1 Controller 2 Second unit System...

Страница 83: ...tal length of the RS485 cable from this unit is 1 200 meters at the maximum 1 1 connection Connect a camera to the RS485 CAMERA port Example When the RS485 cameras are connected to the CAMERA IN connectors 9 and 13 RS485 cable RS485 cable Mode switch No 1 No 4 ON 6 7 8 1 2 3 4 5 ON 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO ...

Страница 84: ...E IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 6 1 2 3 4 5 ON Unit No 10 Termination OFF Unit No 11 Termination OFF Unit No 12 Termination ON Unit No 9 Termination OFF Unit No 2 Termination OFF Unit No 3 Termination OFF Unit No 4 Termination ON Unit No 1 Termination OFF 7 8 Combination cameras RS485 compatible Combina...

Страница 85: ...a terminating switch 2 ON When connecting RS485 cameras Set the termination switch of the connected RS485 CAMERA port to ON Connected to the RS485 CAMERA port 1 Set the RS485 1 termination switch to ON Connected to the RS485 CAMERA port 2 Set the RS485 2 termination switch to ON For 2 wire communication Connected to the RS485 CAMERA port 1 Set the switch No 2 and No 3 to ON Connected to the RS485 ...

Страница 86: ... 0 NC 1 Alarm reset input 2 Emergency recording input 3 4 Earth Grounding 5 Alarm output for available disk space of device con nected to copy port Signal output upon detection of an HDD error 6 HDD error output Signal output upon detection of a camera error 7 Camera error output Signal output upon detection of a unit error 8 Error output Signal output upon completion of outage pro cessing High 12...

Страница 87: ...ming of supplied signals to the sequence changeover input terminal When multiple units are used the sequence timing can be synchronized Setting for the sequence timing can be set with Sequence Timing of Switcher on the SETUP MENU Refer to page 125 For the synchronization of the sequence timing between multiple units there is a difference in the sequence timing setting as shown below between the sy...

Страница 88: ... any camera channel Recording will not be performed for around 4 seconds when the clock is adjusted during recording Terminal block of other units Time adjust output Earth ALARM CONTROL Earth Sensor input Alarm input Alarm reset input Series recording input Time adjust input Earth Alarm output Alarm reset output Alarm recording During recording Disk Buzzer output System error output Temperature er...

Страница 89: ...wer system UPS Then the power supply to this unit can be suspended Connection of the control output When an alarm device such as a buzzer or a lamp is connected the signal output from Pin Nos 15 18 can be used to notify the status by sounding a buzzer or lighting a lamp The following example is of a connection with the HDD error output pin no 16 3 6 Alarming device Relay etc Earth HDD error output...

Страница 90: ...d at an event occurrence Open collector output 24 V 100 mA Event action will be performed according to the setting Non voltage make contact input 100 mA 5 V pull up Alarm signal will be supplied at an event occurrence Open collector output 24 V max 100 mA Remarks w Ch 2 alarm input e Ch 3 alarm input r Ch 4 alarm input t Ch 5 alarm input y Ch 6 alarm input u Ch 7 alarm input i Ch 8 alarm input o C...

Страница 91: ... and the ALARM terminal Terminal Alarm input Alarm output Alarm reset input Emergency recording input Alarm output for available disk space of device connected to the copy port HDD error output Camera error output Error output Outage processing end output Time adjust I O Sequence changeover output Outage detection output External recording mode changeover Alarm suspend output Active time 100 ms or...

Страница 92: ...guration Connection example 1 1 8 2 IN OUT CASCADE OUT 16 16 3 15 15 14 14 13 2 1 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 VIDEO AUDIO IN AUDIO OUT MONITOR OUT CASCADE IN MONITOR VGA ALARM CONTROL SERIAL ALARM POWER COPY 1 MODE EXT STORAGE 10 100BASE T RS485 CAMERA DATA AC IN SIGNAL GND 1 4 2 D sub Pin 9 Female D sub Pin 9 Female This unit PC Locally procured Serial connector of th...

Страница 93: ...selected just before the SETUP MENU Quick was displayed will be displayed in this area Main area The setting items of the selected menu will be displayed in this area Item list of the SETUP MENU Quick Display Perform the display settings such as the display position of the camera title and time and the settings for other basic operations of this unit REC Event Perform the basic settings for record...

Страница 94: ...o the right side of the entered charac ter using the arrows button B Repeat steps 3 and 4 to enter the camera title The available characters for a camera title are different depending on the selected language as follows When any language except RUSSIAN is selected 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z À Ä Â Æ Ç É...

Страница 95: ...n image from camera channel 9 on the upper left area on a 4 split screen 9 12 only for the WJ HD316A Displays images from camera channels 9 12 on a 4 split screen 13 16 only for the WJ HD316A Displays images from camera channels 13 16 on a 4 split screen 1 9 Displays images from camera channels 1 9 on a 9 split screen SETUP MENU LIVE Quick Display REC Event Network Advanced Menu Date Format Time F...

Страница 96: ...buzzer when operating the but tons 8 Language Select a language for the SETUP MENU from the following JAPANESE ENGLISH FRANÇIS ESPAÑOL DEUTSCH ITALIANO RUSSIAN CHINESE Important Displaying the language of the browser used to access the unit from a PC will not be changed even though this setting is changed SETUP MENU LIVE Quick Display REC Event Network Advanced Menu Date Format Time Format Time Da...

Страница 97: ...ill be validated when recording ADVANCED The recording settings set on the SETUP MENU Advanced will be validated when recording Note When QUICK is selected for REC Type of REC Event the SETUP MENU Quick will be displayed by pressing the SETUP ESC button for 2 seconds or more When ADVANCED is selected for REC Type of REC Event the SETUP MENU Advanced will be dis played by pressing the SETUP ESC but...

Страница 98: ... occurrence as long as the alarm is not canceled The following are available for Operation Mode event action mode Refer to page 49 for further information about each event action mode ACT DET Activity Detection Mode Performs only recording writing an event log and camera movement to a preset position at an event occurrence Other event actions will not be performed ALARM Alarm Mode Performs every e...

Страница 99: ...u z Move the cursor to VMD Setup using the arrows button C D and press the SET button Screenshot 2 The VMD Setup pop up menu will be displayed x Select the camera channel to be set by using the arrows button C D c Rotate the jog dial to select ON for a desired camera channel for which the motion detection function is to be applied and press the SET button Screenshot 3 The VMD Area Setup window wil...

Страница 100: ...after changing the line speed the unit will automatically restart 8 HTTP Port Number Specify the HTTP port number to be used to transfer images from this unit It is not necessary to change it for normal use 8 DHCP Select ON or OFF whether or not to use the DHCP server When obtaining IP addresses net mask and a gateway address from the DHCP server set to ON If not set to OFF and enter those address...

Страница 101: ...layed on the left side of the SETUP MENU Advanced The submenus differ depending on the selected main menu Notes The SETUP MENU Advanced will be displayed on monitor 2 and the VGA monitor It is impossible to display the SETUP MENU Advanced on monitor 1 The same images displayed on monitor 2 will be displayed on the VGA monitor Item list of the SETUP MENU About the SETUP MENU Advanced System Basic S...

Страница 102: ...d the time Monitor1 Perform the display settings for monitor 1 such as the camera title display on off the alarm display on off and the time display on off Monitor2 Perform the display settings for monitor 2 such as the display mode task bar style the camera title display position and the camera title display on off Comm Camera Control Set the communication type to control cameras for each camera ...

Страница 103: ...he connected external recording device reaches a specified level Disk Capacity Set to display a warning when the available space of the built in hard disk or of the connected external recording device reaches a specified level Data Delete Delete data stored on the hard disk or format initialize the DVD RAM disk con nected to the COPY port Event Log Display the event log Refer to page 49 for furthe...

Страница 104: ...uick Move the cur sor to Quick Menu using the arrows button C D A B and press the SET button b After completing the settings press the SETUP ESC button for 2 seconds or more to apply the settings The SETUP MENU Advanced will be closed Live images will be displayed again Important If the settings are changed all login users will be forcibly logged out Event Schedule Maintenance Display Comm Switche...

Страница 105: ...sign operating priorities when multiple users access this unit simultaneously from the following Follow the priority Operation by a user with a higher pri ority will be performed When the priorities of the first and the last accessed user are the same post priority will be applied Pre priority Operation by the first accessed user will be performed regardless of priority Post priority Operation by ...

Страница 106: ...8 Time Format Select a display format for the time from the following Ex 3 o clock in the afternoon 12h 3 00 00 PM 24h 15 00 00 8 Time Date Adjust the current time and date Enter year month day hour minute and second in order move the cursor to SET and press the SET button Important Recording will stop for around 4 seconds just after set ting the date and time 8 Auto Adjust Time Select a method fo...

Страница 107: ...U LIVE System Recording Event Display Basic Setup Time Date User Regist User Edit User Delete Host Regist Host Edit Host Delete User Level Save Load Quick Menu Date Format Time Format Auto Adjust Time MASTER Time Summer Time Day Light Saving Summer Time Day Light Saving Table AM JAN 01 03 10 10 10 MMM DD YY OFF SET OFF 10 00 AUTO SETUP 1 2 3 4 5 6 7 8 9 10 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF...

Страница 108: ...it screen 16SCREEN only for the WJ HD316A Displays images from camera channels 1 16 on a 16 split screen SEQ Images will be displayed in the sequential display 8 Camera Partitioning Select a controllable range for each camera channel from the following View Operate Displaying live images and operating the camera are possible View Displaying live images is possible but cameras can not be operated B...

Страница 109: ...cursor to Host Delete and rotate the jog dial to select the host Move the cursor to DELETE and press the SET button The selected host will be deleted User Level Setting of the operation level Set operable functions at each user level LV 1 LV 2 LV 3 Rotate the jog dial to display b to enable operation Leave it blank to disable operation Refer to the table on the next page for each function The defa...

Страница 110: ...ons that can be enabled disabled The following functions can be enabled disabled according to the user level Schedule Comm Switcher SETUP MENU LIVE Recording Event Display Maintenance System Basic Setup Time Date User Regist User Edit User Delete Host Regist Host Edit Host Delete User Level Save Load Quick Menu User Setup Save User Setup Load SAVE LOAD Advanced Function Setup Setup Status Camera S...

Страница 111: ...has started later will be recorded regardless of the operation using the buttons on the front panel or via a network 8 Color Mode Select the color mode for recording from the following COLOR FINE Record images in a high resolution color COLOR STD Record images in a standard resolution color B W Record images in black and white Important When B W is selected for the color mode do not select SFA FQA...

Страница 112: ...dio will be recorded regardless of whether you are displaying on a single screen or a multi screen Audio will not be recorded during pre event recording that is performed in the HDD pre recording area Audio may be recorded fragmentary occasionally Emergency REC Perform the settings for emergency recording Perform the settings for emergency recording such as the recording time or recording rate for...

Страница 113: ...nd lowest recording rates are set will be lower than the set recording rate When the lowest recording rate is applied to three of the camera chan nels this may happen to two of the three channels The following are available for the image quality SFA SFB Top quality SUPER FINE FQA FQB High quality FINE NQA NQB Standard quality NORMAL EXA EXB Low quality EXTENDED A is suitable for less dynamic image...

Страница 114: ...tion area for each camera channel Up to 4 areas can be set for a camera channel for the detection area Refer to page 114 for further information about the motion detection function Screenshot 1 Start operation from the camera channel selection menu of the VMD Setup window z Rotate the jog dial to select ON for a desired camera channel for which the motion detection function is to be applied and pr...

Страница 115: ...tically as A B C and D in the order of creation b To complete the settings rotate the jog dial to select EXIT on the status bar and press the SET button The VMD Setup window will be closed Delete the motion detection area Screenshot 1 Start operation from the VMD Setup window z Rotate the jog dial to select DELETE AREA on the sta tus bar Note After selecting DELETE ALL AREAS pressing the SET butto...

Страница 116: ...of detection in a detection area is available by setting the detection mode Screenshot 1 Start operation from the VMD Setup window z Press the SET button after selecting VMD MODE by rotating the jog dial Screenshot 2 The detection mode menu will be displayed x Set the detection mode Move the cursor to the desired detection mode using the arrows button C D A B Move the cursor on the desired detecti...

Страница 117: ...vent action will be performed according to the set tings when an object keeps moving for the set period in the detection area For example in case of the following settings 10 sec for the areas A and B 20 sec for area C and 30 sec for area D An event action will be performed when an object keeps moving for 10 seconds in area A or B or for 20 seconds in area C or for 30 seconds in area D Alarm Setup...

Страница 118: ...circuited Normally Open N C Signals will be supplied when open circuited Normally Closed Note It is possible to set polarities for each of the alarm inputs 1 16 respectively using a PC via a network Event Schedule Maintenance Display Comm Switcher SETUP MENU LIVE System Recording Event Setup VMD Setup Alarm Setup Terminal Setup Quick Menu N O Terminal Setup Advanced ...

Страница 119: ...and the second lowest recording rates are set will be lower than the set recording rate When the lowest recording rate is applied to three of the camera chan nels this may happen to two of the three channels The maximum rate for each camera channel differs depending on the resolution as follows FRAME 3D ON FRAME 3D OFF 30 ips FIELD 60 ips SIF 30 ips The total of the recording rates of camera chann...

Страница 120: ...min 1 min 30 s 10 s 10 s 7 s 6 s 4 s 3 s 2 s 1 s 10 min 5 min 3 min 2 min 2 min 1 min 30 s 20 s 10 s 10 s 9 s 7 s 4 s 2 s 1 s 20 min 10 min 6 min 5 min 4 min 2 min 1 min 30 s 20 s 20 s 10 s 10 s 9 s 4 s FRAME 3D ON FRAME 3D OFF FIELD SIF When a pre recording area is created in an optional extension unit WJ HDE300 series it is possible to per form pre event recording for up to 60 minutes accord ing...

Страница 121: ...ram and Event Program after setting the time zone Create recording timetables for each day of the week and assign REC Program and Event Program to each timetable Up to 6 recording programs can be created Do the following to create timetables Screenshot 1 Start operation after displaying the timetable window z Press the SET button Schedule Maintenance Display Comm Switcher SETUP MENU LIVE System Re...

Страница 122: ... pin no 24 of the unit will work with the set timetable for EXT Screenshot 3 The pop up settings menu of the timetable for the selected day of the week will be displayed c Select New Time Table Setup using the arrows button C D and rotate the jog dial to check the radio button Screenshot 4 The radio button for New Time Table Setup is checked v Move the cursor to the start time input box for Period...

Страница 123: ...ial days can be set for up to 30 days Perform the settings to specify dates as special days and apply the recording schedule to the special days Schedule Maintenance Display Comm Switcher SETUP MENU LIVE System Recording Event Time Table REC Program Event Program Special Days Quick Menu 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 M M M M M M M M M M M M M M M 1 D D D D D D D D D D D D D D D SUN 16 17 18 1...

Страница 124: ...he jog dial 1 2 16 Displays an image from the selected cam era channel on a single screen 1 4 Displays images from camera channels 1 4 on a 4 split screen 5 8 Displays images from camera channels 5 8 on a 4 split screen 9 9 only for the WJ HD309A Displays an image from camera channel 9 on the upper left area on a 4 split screen 9 12 only for the WJ HD316A Displays images from camera channels 9 12 ...

Страница 125: ...onitor 1 has a black screen OFF Disables the secret view function Screenshot 4 The cursor moves to the PRESET in STEP 1 b Rotate the jog dial to select a preset position number for which image is displayed in STEP 1 from the follow ing 1 256 Moves to the selected preset number Does not move to the preset position n Select DWELL in STEP 1 using the arrows button C D A B Screenshot 5 The cursor move...

Страница 126: ...an external device that can transmit a sequence signal is connected The sequence changeover I O pin no 21 of the ALARM CONTROL connector on the rear panel will supply signals when INT is selected and will receive signals when EXT is selected 8 Auto Skip The settings for Auto Skip are the same as for Monitor1 Refer to page 125 for further information 8 Login Screen The settings for Login Screen are...

Страница 127: ...Setup Monitor 1 Monitor 2 Quick Menu SETUP L UPPER R LOWER WHITE Camera Title Time Date Display Position Camera Title Display Position Line Color on the Multi Screen Advanced Schedule Maintenance Display Comm Switcher SETUP MENU LIVE System Recording Event OSD Setup Monitor 1 Monitor 2 Quick Menu SETUP L UPPER R LOWER WHITE Camera Title Time Date Display Position Camera Title Display Position Line...

Страница 128: ...o be recorded together with images the time display will be recorded in the selected position Refer to page 111 for further information about Embedded REC Time Date 8 Camera Title Display Position Select a camera title display position from the following L UPPER Displays a camera title at the upper left of the screen R UPPER Displays a camera title at the upper right of the screen L LOWER Displays...

Страница 129: ...elect a display mode task bar style from the following Refer to page 13 for further information about the task bar MODE 1 Select MODE 1 for the display mode MODE 2 Select MODE 2 for the display mode MODE 3 Select MODE 3 for the display mode 8 T D and Status Display Position When selecting MODE 1 select the position of the time and date display and the status from the following UPPER Displays them ...

Страница 130: ...IDEO IN connector 1 8 cable compensation Perform the settings for the cable compensation according to the length of cable used S When the length of cable used is shorter than 500 m M When the length of cable used is longer than 500 m and shorter than 900 m L When the length of cable used is longer than 900 m and shorter than 1 200 m Notes Use 5C 2V cables for the cable compensation Perform the set...

Страница 131: ...sed Note When you move the cursor to CANCEL in step 4 and press the SET button the settings will be can celed and the Camera Number Setup menu will be closed RS485 Setup Settings for RS485 Perform the following settings for RS485 Schedule Maintenance Comm Switcher SETUP MENU LIVE System Recording Event Display Camera Control PS DATA Setup RS485 Setup RS232C Setup NW Setup 1 NW Setup 2 NTP Setup Qu...

Страница 132: ...tem is a unique number assigned to each system device The addresses must be unique to identify system devices when connecting multiple system devices Numbers 001 099 are to be assigned as the unit addresses for the system devices 8 Baud Rate Select the communication speed for data transmission with a connected device from the following 9 600 19 200 38 400 bps Schedule Maintenance Comm Switcher SET...

Страница 133: ...user level setting of the authen ticated user It is impossible to operate the unit from an unregistered host 8 Line Speed The following are available for Line Speed AUTO Line speed will be applied automatically 10 HALF 10 Mbps half duplex 10 FULL 10 Mbps full duplex 100 HALF 100 Mbps half duplex 100 FULL 100 Mbps full duplex Note When the SETUP MENU is closed after changing the line speed the unit...

Страница 134: ...e also available for the domain name Note The first character of the host name and the domain name must be a letter a z Do not begin with a num ber or a symbol character NTP Setup Time adjustment of network Perform the following settings for time adjustment 8 Time Adjustment Select ON and OFF whether or not to adjust the time with reference to the NTP server ON Adjusts time with reference to the N...

Страница 135: ... 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips 1ips CAM 1 CAM 2 CAM 3 CAM 4 CAM 5 CAM 6 CAM 7 CAM 8 CAM 9 CAM 10 CAM 11 CAM 12 CAM 13 CAM 14 CAM 15 CAM 16 MANU SCHE POST EVT EMR PRE EVT SETUP MENU Event Schedule Display Comm Switcher LIVE Recording Sy...

Страница 136: ...omatically when the set number of days has passed from the day the image was recorded Refer to a system administrator for further information The number of days for the auto delete function is as fol lows The auto delete function will not work when OFF is selected OFF 1DAY 2DAYS 3DAYS 4DAYS 5DAYS 6DAYS 7DAYS 8DAYS 9DAYS 10DAYS 14DAYS 30DAYS 45DAYS 60DAYS 90DAYS 120DAYS 150DAYS 180DAYS Note Images ...

Страница 137: ...Date Event Indication R ERR X Y REMOVE X Y X indicates the unit unit number that has the hard disk error Y indicates the disk number in the unit unit number X indicates the unit unit number that has the hard disk that has been removed from the subject for recording Y indicates the disk number in the unit unit number Failed to read data on the HDD Auto removal of the link FULL indicates the partiti...

Страница 138: ...hat has the hard disk error Y indicates the unit unit number Hour meter warning PROTECT indicates the port number to which the external recording device is connected Disk has a write protection NO DISK indicates the port number to which the external recording device is connected Disk is not inserted MEDIUM indicates the port number to which the external recording device is connected Incompatible d...

Страница 139: ...D309A to complete the camera setting Notes To display the special menu of the camera setup menu press the camera selection button 2 after moving the cursor to SPECIAL on the camera setup menu To reset the settings of the camera setup menu to the default settings do the following 1 Display the SPECIAL menu of the camera setup menu by pressing the camera selection button 2 after moving the cursor to...

Страница 140: ...al recording area is not created manual recording images and schedule recording images are recorded into the event recording area If the event recording area is not creat ed event recording images and emergency recording images are recorded into the normal recording area How to replace the built in hard disk It is possible to replace the hard disk drive regardless of whether the power of the unit ...

Страница 141: ...er hard disk drive When removing hold the hard disk drive securely to prevent it from falling After removing the four screws detach the hard disk drive from the hard disk drive mounting angle 6 Install the new hard disk drive in the reverse order used for detaching the hard disk drive Confirm that the hard disk drive is set as master using the jumper connector Important When installing confirm tha...

Страница 142: ... front panel and start replacing the built in hard disk Start from step 2 on page 140 to replace the built in hard disk Important Detach the cable from the front panel after confirming that the OPERATE indicator on the front panel is not lit Otherwise it may cause malfunction The OPERATE indicator on the front panel will light by attaching the cable to the front panel The power will be supplied to...

Страница 143: ...l extension unit Information about hard disk located in the main unit and optional exten sion unit ERROR Indicates that the hard disk has failed to be initial ized Important It is impossible to operate the unit when there is a hard disk with indications of capacity ERROR LOST or ERROR In this case remove the relevant hard disk Refer to page 151 Hard disks with ADD capacity indication are not initi...

Страница 144: ... without the RAID 5 function at the same time When the RAID 5 function is used it is impossible to use two hard disks in this unit The recorded pictures in those disks will not be deleted RAID 5 Function of the Extension Unit Setup cancel the RAID 5 function Do the following to set or cancel the RAID 5 function with an optional extension unit Refer to the operating instructions of the extension un...

Страница 145: ...isplayed when using the RAID 5 function Screenshot 4 The RECORDING AREA SETUP OF ALL DISKS will be dis played m Select a recording area using the arrows button A B and rotate the jog dial to set the capacity for the select ed recording area Repeat this operation to set the capacity for the other recording areas Digital Disk Recorder WJ HD300A HDD DISK MENU TOP MENU FORMAT MIRROR ON REMOVELINK REST...

Страница 146: ...ursor to SELECTED DISK using the arrows button A B and press the SET button When using the RAID 5 function select ONE UNIT on THE CANDIDATE FOR A FORMAT menu Digital Disk Recorder WJ HD300A HDD DISK MENU THECANDIDATEFORAFORMAT RECORDINGAREASETUPOFALLDISK RETURN SETUP ESC OK SET HDD Total capacity 2790GB Normal area Event area 90GB 1800GB Copy area 450GB Free area 450GB EXECUTE CANCEL Starting form...

Страница 147: ... A FORMAT DISK SELECT RETURN SETUP ESC OK SET 160GB 160GB 160GB 160GB 160GB ADD 160GB 160GB LOST MAIN EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 160GB 160GB 160GB 160GB ERROR ADD ERROR 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 1 2 3 4 Select HDD to be formatted and press SET key Digital Disk Recorder WJ HD300A HDD DISK MENU THE CANDIDATE FOR A FORMAT UNIT SELECTION RETU...

Страница 148: ... areas 2 Press the SET button after setting Digital Disk Recorder WJ HD300A HDD DISK MENU DISK SETTING METHOD PRE RECORDING AREAS RETURN SETUP ESC OK SET HDD Total capacity 160GB 1CH 2CH 3CH 4CH 5CH 6CH 7CH 8CH 0GB 9CH 0GB 0GB 10CH 0GB 0GB 11CH 0GB 0GB 12CH 0GB 0GB 13CH 0GB 0GB 14CH 0GB 0GB 15CH 0GB 0GB 16CH 0GB FREE 0GB Digital Disk Recorder WJ HD300A HDD DISK MENU DISK SETTING METHOD DETAILED SE...

Страница 149: ... 160GB 160GB 160GB 160GB 160GB 160GB 160GB 160GB 1 2 3 4 Setting for Mirroring Screenshot 2 The password entry window will be displayed c Enter the password for an administrator by rotating the jog dial The camera selection buttons 1 10 0 for the WJ HD316A 1 9 0 for the WJ HD309A are available to enter numbers for the password The same method is used to enter insert and delete characters as for at...

Страница 150: ...ry MIRROR ON Do the following to recover the hard disk when one of the hard disks involved in mirroring is damaged while mirroring or when one of the hard disks is replaced By completing the following procedures recovery of the hard disk will start when the unit is in operation after the HDD DISK MENU is closed z Turn on the power of this unit An image saying that the system check has been com ple...

Страница 151: ...splayed Press the SET button after the image is displayed Note When the hard disk is replaced or removed the TOP MENU of the HDD DISK MENU will be auto matically displayed Screenshot 1 The TOP MENU of the HDD DISK MENU will be dis played x Move the cursor to REMOVE LINK using the arrows button A B and press the SET button Digital Disk Recorder WJ HD300A HDD DISK MENU TOP MENU FORMAT MIRROR ON REMO...

Страница 152: ...ecorder WJ HD300A HDD DISK MENU TOP MENU REMOVING REMOVING MAIN REMOVED OK EXT1 4 REMOVED OK EXT2 1 REMOVED OK EXT2 2 REMOVED OK EXT5 3 REMOVED OK EXT6 1 REMOVED OK EXT6 2 REMOVED OK EXT6 3 REMOVED OK EXT6 4 REMOVED OK EXT7 1 REMOVED OK Digital Disk Recorder WJ HD300A HDD DISK MENU TOP MENU FORMAT MIRROR ON REMOVELINK RESTART EXIT MIRROR OFF 160GB M 160GB 160GB 160GB 160GB ADD 160GB 160GB LOST MAI...

Страница 153: ...ion command A command shown in the Command List is designated ETX This shows the data end ETX ASCII code 03h is always prefixed to data The character code is ASCII When a command needs a parameter a colon is used for dividing the command and parameter The following shows how to write the commands when two or more commands are specified 2 Response Command from the Unit to the PC The unit sends back...

Страница 154: ... SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP ETX When receiving the command above this unit will start the login procession of the user name of ADMIN 2 This unit PC Response against 1 STX AD001 OLI 1 ETX 3 PC This unit Select the monitor 2 STX AD001 OMS 0002 ETX 4 This unit PC Response against 3 STX AD001 OMS 0002 ETX 5 PC This unit Display images from the camera channel 1 STX AD001 OCS 00001 ...

Страница 155: ...digit or range of the command parameters is incorrect 301 Command invalid The unit does not support the operation mode E Command error ASCII code 45H ER N ETX Error 9 PC This unit Logout STX AD001 OLO ETX When receiving the command above the user logged in via SERIAL RS232C ADMIN will log out 10 This unit PC Response against 9 STX AD001 OLO ETX Note The character code of STX ETX and SP are as foll...

Страница 156: ...b Pin 9 Female This unit PC Pin No Signal Name I O 1 CD IN 2 RXD IN 3 TXD OUT 4 DTR OUT 5 SG 6 DSR IN 7 RTS OUT 8 CTS IN 9 RI IN 5 1 9 6 As viewed from the rear of the WJ HD316A WJ HD309A 7 RTS 8 CTS 3 TXD 5 GND 2 RXD 7 RTS 8 CTS 3 TXD 5 GND 2 RXD WJ HD316A WJ HD309A PC or another device Cross cable connection example 4 PC Connection Example An RS232C crossing cable is used for connection between ...

Страница 157: ... ASCII nn 01 99 Sequence number ddd ddd text 200 bytes or less n P Stops PLAY n R Stops REC no parameter stops PLAY and REC n 0F Normal speed n 1F x2 speed n 2F x5 speed n 3F x10 speed n 4F x20 speed n 5F x50 speed n 6F x100 speed n 0S Normal speed n 1S 1 2 speed n 0F Normal speed n 1F x2 speed n 2F x5 speed n 3F x10 speed n 4F x20 speed n 5F x50 speed n 6F x100 speed n 0S Normal speed n 1S 1 2 sp...

Страница 158: ...CII OAI ZAI nn OAL MAD n ALD n ALM b1b2b3a1a2a3a4 Parameter ASCII b1b2b3 Head alarm CH information binary a1a2a3a4 Alarm CH information binary b1b2b3 Head alarm CH information binary a1a2a3a4 Alarm CH information binary nn 01 99 Sequence No ddd ddd text 200 bytes or less n 0 Alarm all reset n 1 Alarm reset n 0 Alarm suspension OFF n 1 Alarm suspension ON n 0 LED OFF n 1 LED ON n 2 LED Blinking b1b...

Страница 159: ...or m 1 Copy to media connected to COPY 1 m 2 Copy to media connected to COPY 2 y1y1y1y1m1m1d1d1h1h1n1n1 Start date time of data copy y2y2y2y2m2m2d2d2h2h2n2n2 End date time of data copy s 0 Format to specify the camera CH Fixed to 0 ccc Camera CH No of target for data copy m 0 Copy to HDD copy sector m 1 Copy to media connected to COPY 1 m 2 Copy to media connected to COPY 2 y1y1y1y1m1m1d1d1h1h1n1n...

Страница 160: ... n 4 13 segments n 5 16 segments oqt 01F Sequence activated ozm 0 Zoom OFF ozm 2 x2 zoom ozm 4 x4 zoom opa Currently playback is being paused opl Currently playback is being performed orc Currently recording is being performed osf n Currently fast playback is being per formed osp p Currently playback is being stopped osp r Currently recording is being stopped osr n Currently fast reverse playback ...

Страница 161: ...inuous External timer recording mode m 0 Live m 1 Live sequence m 2 Playback m 3 Other statuses a1a2a3a4 Camera CH information binary yyyymmddhhnnss Playback time Recording status nn 00 Recording stop nn 01 Manual recording activated nn 02 Event recording activated nn 03 Schedule recording activated nn 04 Emergency recording activated sss Unit address nn Sequence number rrrrrrrrrrrrrrrr Record num...

Страница 162: ...rrrrrrrrr ccc q nnnn yyyymmdd hhnnss nnss t ssssss rrrrrrrrrrrrrrrr Record number ccc Camera CH q picture quality 0 Super Fine 1 Fine 2 Normal 3 Extended nnnn Recording rate yyyymmddhhnnss Recording start date and time nnss Recording total time t 0 Text included t 1 Text not included ssssss Record size KB Item Transmission command ASCII Response command ASCII Parameter ASCII ...

Страница 163: ...System Host Edit System Host Delete System User Level System Save Load Time Date Summer Time Day Light Savings Table Comm PS Data Setup Comm RS485 Setup Comm RS232C Setup Comm NW Setup 1 Comm NW Setup 2 Comm NTP Setup RS485 Setup Control Camera CH PS Data Setup Camera Number Setup Display Monitor 1 Display Monitor 2 OSD Setup Camera Title Monitor 1 Live Sequence Switcher Monitor 2 Monitor 2 Live S...

Страница 164: ... 16 WJ HD309A CAM1 CAM2 CAM9 QUAD1 4 QUAD5 8 QUAD9 9SCREEN 1 2 256 1 s 2 s 30 s 2 s Summer Time IN OUT AUTO OUT Day Light Savings Beep Operation ON OFF OFF Language JAPANESE ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO RUSSIAN CHINESE ENGLISH REC Event REC Type QUICK ADVANCED QUICK Resolution FRAME 3D ON FRAME 3D OFF FIELD SIF FIELD Manual REC REC Rate OFF 2 ips 3 ips 5 ips 6 ips 7 5 ips 10 ips 15 ip...

Страница 165: ... 1 00 23 00 0 00 Summer Time Day Light Savings IN OUT AUTO OUT Summer Time Day Light Savings IN Last Sunday of March at 2 00 a m Table OUT Last Sunday of October at 2 00 a m Setup Menu Setup Item Parameter Default Setting 1 Power ON Manual REC ON OFF OFF VMD Setup SETUP AREA SETUP ALL AREA DELETE AREA DELETE ALL AREA SENSITIVITY LOW MID HIGH OFF OFF VMD MODE ANY AREA VECTOR DURATION ANY AREA EXIT ...

Страница 166: ...View Operate View View Operate when using PC View Operate when using PC via a network via a network User Level Setup LV1 LV2 LV3 LV1 Setup Status LV1 LV2 LV3 LV1 LV2 Camera Setup LV1 LV2 LV3 LV1 Event Log Status LV1 LV2 LV3 LV1 LV2 Access Log Status LV1 LV2 LV3 LV1 LV2 Error Log Status LV1 LV2 LV3 LV1 LV2 Alarm Reset LV1 LV2 LV3 LV1 LV2 Alarm Suspended Time LV1 LV2 LV3 LV1 Copy LV1 LV2 LV3 LV1 Nor...

Страница 167: ... Camera channel with a video loss occurrence N Terminal Command Alarm Same number for camera channel number and alarm number Monitor2 Action HD316A OFF CAM1 CAM2 CAM16 VMD OFF HD309A OFF CAM1 CAM2 CAM9 Video Loss Camera channel with a video loss occurrence N Terminal Command Alarm Same number for camera channel number and alarm number VMD Setup SETUP AREA SETUP ALL AREA DELETE AREA DELETE ALL AREA...

Страница 168: ...m Mail Notice ON OFF OFF N FTP Alarm Sending ON OFF OFF N Special Days DATE 1 1 to 12 31 Mode MON TUE WED THU FRI SAT SUN Switcher Monitor1 Live Sequence Operating with the buttons of the unit HD316A STEP1 CAM1 WJ HD316A STEP2 CAM2 STEP16 CAM16 1 2 16 1 4 5 8 9 12 13 16 1 9 10 16 HD309A STEP1 CAM1 WJ HD309A STEP2 CAM2 STEP9 CAM9 1 2 9 1 4 5 8 9 9 1 9 Operating via a network WJ HD316A CAM1 CAM2 CAM...

Страница 169: ...ition L UPPER R UPPER L LOWER R LOWER R UPPER CENTER Line Color on the Multi Screen WHITE GRAY BLACK WHITE Monitor1 Time Date Display ON OFF ON Camera Title Display ON OFF ON Alarm Display ON OFF ON Monitor2 Display Mode MODE1 MODE2 MODE3 MODE1 T D and Status Display UPPER LOWER LOWER Position Camera Title Display ON OFF ON Comm Camera Control COMP S M L HD316A CAM1to CAM8 S HD309A CAM1 to CAM6 S ...

Страница 170: ...CP ON OFF OFF IP Address 000 000 000 000 to 254 254 254 254 192 168 0 250 Subnet Mask 000 000 000 000 to 255 255 255 255 255 255 255 000 Gateway 000 000 000 000 to 254 254 254 254 192 168 000 001 DNS ON OFF OFF Primary 000 000 000 000 to 254 254 254 254 000 000 000 000 Secondary 000 000 000 000 to 254 254 254 254 000 000 000 000 DDNS ON OFF OFF NW Setup2 User Name User Password Access Interval 10 ...

Страница 171: ...N OFF OFF N Mail Server Address N Send to N Address1 N Address2 N Address3 N Address4 N From Address N POP before SMTP ON OFF OFF N POP Server Address N User Name N User Password N Maintenance Disk Info Warning for Disk Life Time 10 000 h 20 000 h 30 000 h 20 000 h HDD Safety Mode ON OFF OFF U Disk End Mode Normal Recording Area CONTINUE STOP CONTINUE Event Recording Area CONTINUE STOP CONTINUE Co...

Страница 172: ...e SETUP MENU on the monitors Check the level settings of the users logging in Check if monitor 1 is used to display the SETUP MENU The SETUP MENU cannot be displayed on monitor 1 Check if the cable connections are correct Check the brightness and contrast settings of the moni tors Can the users display camera images on the monitors Check the level settings of the users logging in Power is not turn...

Страница 173: ...HD309A Check if the camera you are going to control is a combina tion camera Check the camera control settings Can the users control the cameras Check the level settings of the users logging in Check the BUSY indicator When the indicator is lighting a higher priority user is controlling the cameras You can not control the cameras until the indicator goes out Can the users record images Check the l...

Страница 174: ...he built in backup battery has been charged enough If not so supply power to the unit for 48 hours or more to recharge the battery Check if HDDs were added or removed If so the HDD DISK MENU will be displayed automatically If the HDD DISK MENU is displayed even though no HDDs were added or removed refer to the dealer The HDD may have some trouble Check if the built in backup battery has been worn ...

Страница 175: ... unit and PC Check if the network is crowded The power cord plug and connectors are worn out This may result in electric shock or a fire Unplug the power plug from the AC outlet immediately and refer to qualified service personnel Check if there is a partition in the HDD Check if there is a partition in the HDD Refer to p 136 Refer to p 136 Refer to the Network Setup Instructions PDF Refer to p 10...

Страница 176: ...D316A 1 V P P 75 Ω active loop thru output x8 1 to 8 CH BNC 1 1 V P P 75 Ω loop thru output x8 9 to 16 CH BNC WJ HD309A 1 V P P 75 Ω active loop thru output x8 1 to 8 CH BNC 1 1 V P P 75 Ω loop thru output x1 9 CH BNC 1 V P P 75 Ω x2 BNC RGB output x1 15 pin D sub Y 1 V P P 75 Ω C 0 286 V P P 75 Ω x1 S video output connec tor 1 V P P 75 Ω x1 RCA pin 10 dBv 10 KΩ unbalanced x4 RCA pin High speed se...

Страница 177: ... Controllers PDF Administrator Console Software Others RS 485 ports RS 485 full duplex half duplex 7 x2 RJ 11 DATA ports RS 485 x2 RJ 11 SERIAL connector RS 232C x1 9 pin D sub Ethernet port 10 Base T 100 Base Tx RJ 45 1 When power is not supplied the video output signal was not sent from the unit even if a video input signal is supplied 2 Non voltage N O Contact 50 KΩ 5 V pull up 3 Open collector...

Страница 178: ...nications Security Company Unit of Matsushita Electric Corporation of America Security Systems Group www panasonic com cctv Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Zone Office Eastern One Panasonic Way Secaucus NJ 07094 201 348 7303 Central 1707 N Randal Road Elgin IL 60123 847 468 5205 Western 6550 Katella Ave Cypress CA 90630 714 373 7840 2004 Matsushita Electric Indust...

Страница 179: ...plete the following window will be displayed COPY DRIVE Destination disk SIZE Size of the recorded images to be copied Available disc space Available disk space size of the destination disk When the available disk space is smaller than the size of the recorded images the recorded images will be copied corresponding to the available disk space To display to the DATA COPY window again press the SETU...

Страница 180: ...an the size of the recorded images the recorded images will be copied corresponding to the available disk space Click the CLOSE button to close the calculation result win dow Notes When the available disk space is displayed as KB check the following Check if Disk End Mode is set to STOP Refer to the Network Setup Instructions Check if the selected COPY DRIVE is correct Check if the media is format...

Страница 181: ...the illustration description on pages 92 and 93 as follows Page 92 Updated image of the Network Setup 1 menu Page 93 Updated description about Live Video Quality Select FQB or NQB QVGA for Live Video Quality FQB High quality default NQB QVGA Low quality Suitable when there are difficul ties in displaying images depending on the traffic of the network Note When NQB QVGA is selected image display ar...

Страница 182: ...P NM0805 0 3TU001442AAA Printed in Japan ...

Отзывы: