83
SPECIFICATIONS
●
General
Power supply :
220 - 240 V AC, 50 Hz
Power consumption :
13 W max.
Weight :
4 k
g
Dimensions :
420 (W)
×
44 (H)
×
350 (D) mm (no rubber feet and bosses included)
Applicable line :
ISDN BRI dial-up (1B/2B)
Video input :
Video input 1 - 5, composite / 1 V[p-p]/75
Ω
BNC
Note) Video input 1 is for combination camera control signal multiplexed.
Local output :
Composite, 1 V[p-p]/75
Ω
, BNC, selected video input to be output.
Video output :
Monitor 1 (menu provided), 2 (No menu provided), composite,
1 V[p-p]/75
Ω
, BNC
Image compression system :
H.263/H.261 (automatic selection)
No. of processed picture elements CIF: 352
×
288 max. 15 fps
Audio input/output :
Audio input
×
1, audio output
×
1, RCA pin jack: –10 dB
Audio compression system :
G.728 (/G.711): audio band 3.4kHz, G.722: audio band 7 kHz, or no sound
●
Control System
Data port* :
4-wire RS-485, RJ-11 connector, baud rate = 4 800 bps/ 9 600 bps,
Data length = 7-bit/8-bit
Stop = 1-bit/2-bit, parity = NONE/ODD/EVEN
Parallel port :
D-Sub 25-pin female, Input
×
8 (make-contact),
Output
×
8 (open collector output)
Forced (line) disconnection input
×
1 (make-contact)
Clock adjust signal input
×
1 (make-contact)
Mid-communication output
×
1 (open collector output)
Parallel data strobe output
×
1 (open collector output), +12 V output (50 mA max.)
Sensor input/trigger output :
D-Sub 25-pin female, sensor input
×
8 (make-contact)
Trigger output
×
8 (open collector output)
Host port :
RS-232C (D-Sub 9-pin male) or 4-wire RS-485 (RJ-11 connector),
Rate = 4 800/9 600/19 200 bps, data length = 8-bit (fixed),
Stop = 1-bit (fixed), Parity = NONE
Note) RS-232C fixed or RS232C/RS485 changeover by DCD signal (Set with dip
switches on the rear)
* Daisy chain not permissible.
●
Operation System
Remote control connector :
Rear: RJ-11 modular port, front: mini-DIN 5-conductor jack
ISDN terminating switch :
100
Ω
termination ON/OFF
Host port, data port
RS-485 terminating SW :
ON/OFF (Set with dip switches on the rear)
Data port RS485 line changeover SW :
Straight/crossover (Set with dip switches on the rear)
Note 1:
Mutual connections with Codec by other firms are not guaranteed.
Note 2:
In case of no ISDN, contract additional proceedings for subscription are required. This unit does not include the DSU
(Digital Service Unit). The DSU is needed separately. The DSU to be used should be qualified as an electric commu-
nications terminal unit.
Weight and dimensions indicated are approximate.
Specifications are subject to change without notice.