57
6 0 0 M A I N T E N A N C E
6 1 0 A L A R M L O G
↓
6 2 0 R E M O T E C L O C K S E T
↓
6 3 0 C O M R A T E / I N F O .
↓
6 4 0 C A L L I N G L O G
↓
6 5 0 S E R I A L D A T A P O R T
↓
6 6 0 L O O P B A C K R E Q U E S T
↓
6 7 0 V E R S I O N
↓
6 8 0 M O D E D I S P .
↓
6 9 0 I N I T I A L I Z E
↓
↑ ↓
: M O V E E N T : S E L E C T E S C : P R V
The maintenance function is used to check the alarm and calling logs, system version, etc.
This may also be used to initialize the directory and system settings. During communication, the status and version of the
remote (transmitter) site can be checked.
0 0 0 T O P
1 0 0 M O D E
↓
( T R A N S M I T T E R )
2 0 0 R E C E I V I N G R E G I .
↓
3 0 0 D I R E C T O R Y / D I A L I N G R E G I .
↓
4 0 0 S E T U P
↓
- - - - - - - -
↓
6 0 0 M A I N T E N A N C E
↓
7 0 0 R E M O T E S E T U P E D I T
↓
↑ ↓
: M O V E E N T : S E L E C T E S C : C L E A R
d
1
Move the cursor to item 600 in the TOP menu
by pressing the
▲
or
▼
button. Then press
the ENTER button.
The
[600 MAINTENANCE]
menu appears on the monitor
screen.
2
Move the cursor to the desired item by
pressing the Direction buttons. Then press
the ENTER button.
The selected item submenu appears on the monitor screen.
610:
Recalls the alarm log from the remote site and
the alarm dialing log received at the control site.
620:
Sets the clock in the remote site to the time of the
clock in the control site.
This is only applied when controlling the codec
from the control site while the line is connected.
630:
The reason for connection failure by line discon-
nections due to some fault during communication
can be checked.
640:
Displays the log of calls received during commu-
nication and logs of calls received or made.
650:
Serial port settings of the remote (transmitter) site
can be checked during communication.
660:
To check the environment of the local and remote
sites by loopback video/audio test.
670:
To check the system version.
680:
To check the audio and video quality
690:
To initialize the directory or system.
HOW TO USE THE MAINTENANCE FUNCTION
■