43
4
Set alarm interlock availability.
This item lets you enable or disable alarm activation when
an alarm is received from the associated alarm sensor con-
nected to the SENSOR IN/TRIGGER OUT port on the rear of
the AV Codec.
The sensor input terminal number of the SENSOR IN/TRIG-
GER OUT port corresponds to the view point number.
Move the cursor to the ALARM field and select either ON or
OFF by pressing the Direction button. Then press the
ENTER
button.
ON:
Enables alarm activation
OFF: Disables alarm activation
5
Repeat the above procedure to set the other
view point numbers.
6
Set a default view point
This item lets you select a display pattern for your startup
screen when the power is turned on or when communica-
tion is terminated.
The sequence will begin with the number set in this step
when the sequential function is operated.
N o . C A M P R S T T R G A L A R M
●
1 . 1 1
. O N O F F
●
2 . 2
■
. O N O F F
●
3 . 3
■
. O N O F F
●
4 . 4
■
. O N O F F
●
5 . 5
■
. O N O F F
●
9 . 1 6
. O N O F F
●
7 . 1 7
. O N O F F
●
8 . 1 8
. O N O F F
Alarm interlock ON/OFF
Triggers (1 to 8)
• The video set for the default view point is stored in
the internal memory for pre-frames before the alarm
activation. (This applies when the sequential scan is
set to OFF.)
• Set the default number to [0] when the combination
camera is used in the SEQ mode of the camera setup
menu.
Note