136
<Model: Water System>
(Note)
• All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).
• “O” marked parts are recommended to be kept in stock.
[PHAAM] Printed in Malaysia
SSYW1007 - 00
REF.
NO.
DESCRIPTION & NAME
QTY.
WH-MDC09C3E5
WH-MDC12C6E5
WH-MDC14C6E5
WH-MDC16C6E5 REMARKS
1
BASE PAN
1
CWD52K1242
←
←
←
2
HOT WATER COIL-COMPLETE
1
CWB90C1046
←
←
←
O
3
RECEIVER
1 CWB141039
←
←
←
4
FLOAT (FLOW SWITCH)
1
CWB601008
←
←
←
O
9
PUMP
1 CWB532096
←
←
←
O
16
BOTTLE COMPLETE
1
CWH90C0018
CWH90C0013
←
←
17
HEATER ASS'Y
1
CWA34K1026
CWA34K1025
←
←
O
18
SOUND PROOF MATERIAL
1
CWG302593
CWG302592
←
←
18a
SOUND PROOF MATERIAL
1
CWG302594
←
←
←
19
THERMOSTAT
2/3 CWA151065
←
←
←
O
20
ELECTRONIC CONTROLLER
- MAIN
1 CWA73C4889R
CWA73C4891R
CWA73C4893R
CWA73C4895R
O
21
TERMINAL BOARD ASS'Y
1
CWA28K1200
←
←
←
25
TERMINAL BOARD ASS'Y
1
CWA28K1211
←
←
←
26
TERMINAL BOARD ASS'Y
1
CWA28K1221
←
←
←
27
ELECTRO MAGNETIC SWITCH
1
K6C1AYY00004
←
←
←
O
28
TERMINAL BOARD ASS’Y
1
CWA28K1222
←
←
←
29
RESIDUAL CURRENT CIRCUIT
BREAKER
2/3
CWA181005
←
←
←
O
30
TRANSFORMER-COMPLETE
1 CWA40C1075
←
←
←
O
31
SENSOR-COMPLETE
1 CWA50C2749
←
←
←
O
32
REMOTE CONTROL COMPLETE
1
CWA75C3689
←
←
←
O
33
PRESSURE GAUGE
1
CWB070001
←
←
←
O
34
PRESSURE RELIEF VALVE
1
CWB621011
←
←
←
O
39
OPERATING INSTRUCTION
1
CWF567726
←
←
←
40
INSTALLATION INSTRUCTION
1
CWF614606
←
←
←
42
TUBE CONNECTOR-COMPLETE
1
CWT29C1050
←
←
←
43
TUBE CONNECTOR-COMPLETE
1
CWT29C1055
←
←
←
44
CONTROL BOARD COVER
1
CWH131420A
←
←
←
45
HANDLE
2 CWE161014
←
←
←
46
CABINET SIDE PLATE ASS’Y
1
CWE04K1060A
←
←
←
47
CABINET FRONT PLATE
1
CWE061275A
←
←
←
48
CRANKCASE HEATER
1
CWA341071
←
←
←
Содержание WH-MDC09C3E5
Страница 14: ...14 4 Location of Controls and Components 4 1 Monobloc Unit ...
Страница 17: ...17 ...
Страница 18: ...18 ...
Страница 19: ...19 4 1 2 2 Weekly Timer Setting ...
Страница 20: ...20 4 1 2 3 Setting Up The Special Functions ...
Страница 21: ...21 5 Dimensions 5 1 Monobloc Unit ...
Страница 22: ...22 6 Refrigeration And Water Cycle Diagram ...
Страница 23: ...23 ...
Страница 24: ...24 7 Block Diagram 7 1 WH MDC09C3E5 ...
Страница 25: ...25 7 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 26: ...26 8 Wiring Connection Diagram 8 1 WH MDC09C3E5 ...
Страница 27: ...27 ...
Страница 28: ...28 8 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 29: ...29 ...
Страница 30: ...30 9 Electronic Circuit Diagram 9 1 WH MDC09C3E5 ...
Страница 31: ...31 ...
Страница 32: ...32 9 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 33: ...33 ...
Страница 34: ...34 10 Printed Circuit Board 10 1 Water System 10 1 1 Main Printed Circuit Board ...
Страница 35: ...35 10 1 2 Solar Printed Circuit Board Optional ...
Страница 36: ...36 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 37: ...37 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Страница 38: ...38 11 Installation Instruction Monobloc Unit Dimension Diagram ...
Страница 39: ...39 Main Components ...
Страница 52: ...52 Solar Priority is Set Solar Priority is Not Set ...
Страница 55: ...55 Heat Tank Heating No Priority Solar Priority Set ...
Страница 56: ...56 Heat Tank Heating No Priority Solar Priority Not Set ...
Страница 66: ...66 Solar Priority Not Set Heat Tank Mode Heating Priority Set ...
Страница 67: ...67 Tank Mode Solar Priority Set Solar Priority Not Set ...
Страница 115: ...115 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 118: ...118 17 10 To Remove Bottle Complete When reinstall the water pipe use grease or water at the joining ...
Страница 130: ...130 ...
Страница 134: ...134 19 2 WH MDC09C3E5 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 Water System ...