background image

1

ADVANCED ELECTRIC HEATING

Richmond DPL & DP

Low Level & Full Height Thermal Electric Radiator

Installation and Operation Guide

Type

Wattage

No. of Fins

Size (WxHxD) (mm)

Net Weight (kg)

DPL 10

950

10

865 340

96

12.8

DPL 15

1425

15

1265 340

96

19.2

DP 450

450

3

310 575

96

6.1

DP 600

600

4

390 575

96

8.1

DP 900

900

6

550 575

96

11.8

DP 1200

1200

8

710 575

96

15.7

DP 1500

1500

10

870 575

96

19.3

DP 1800

1800

12

1030 575

96

25.7

Models

v10 20171214

E1400226

Содержание Richmond DP 1200

Страница 1: ...e Type Wattage No of Fins Size WxHxD mm Net Weight kg DPL 10 950 10 865 340 96 12 8 DPL 15 1425 15 1265 340 96 19 2 DP 450 450 3 310 575 96 6 1 DP 600 600 4 390 575 96 8 1 DP 900 900 6 550 575 96 11 8 DP 1200 1200 8 710 575 96 15 7 DP 1500 1500 10 870 575 96 19 3 DP 1800 1800 12 1030 575 96 25 7 Models v10 20171214 E1400226 ...

Страница 2: ...ir around the radiator Important Safety Information Whilst in operation the appliance must not be covered to avoid over heating If the appliance is covered and the safety over heat switch is activated the element will need replacing This is not covered by the warranty This appliance is a Class 2 double insulated appliance and should not be used or connected in the wet zone of a bathroom or kitchen...

Страница 3: ... been given supervision or instruction concerning use of the applince in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Somepartsofthisproductcanbecomeveryhotandcauseburns Particular attention has to be given where children and vulnerable people are present ...

Страница 4: ...l heat conducting fluid filled inside the fins with a unique procedure assuring a bubble free content for a total uniform and silent delivery of heat Fitting the Appliance The appliance should be hung as close as possible to the coolest wall in the room however it is not recommended to place it on a wall that is not properly insulated if this is the case the part of the wall behind the unit should...

Страница 5: ...s ensuring the brackets are installed in the correct position figure 2 Figure 2 Once the brackets have been installed the radiator can be hung from the supports figure 3 To lock the radiators in place press on the ratchet and turn until a click is heard figure 4 Figure 3 Figure 4 Unlocked Locked ...

Страница 6: ...sion of 0 3ºC Controller Buttons and Symbols Switching On Once power has been supplied to the radiator it will initially be in the standby mode Setting the Clock 1 In the Stand by mode press and hold the time and button for more than 3 seconds 2 Press the or button to select current day of the week 3 Press the Mode button to set the time using the or button ...

Страница 7: ...tinuously for more than 5 seconds will change the temperature rapidly The temperature ranges between 7ºC and 32ºC Economy Temperature Setting Press the Mode button until economy is selected then press the or to adjust the temperature Pressing either button continuously for more than 5 seconds will allow the value to change rapidly Frost Protection Setting Press the Mode button until frost protecti...

Страница 8: ...ramme whether the radiator is programmed as either comfort or economy respectively for each hour 3 Use the Mode key to move to the next day until the whole week is completed at which point it will return to the stand by mode To accept this programme turn the radiator back on and select P3 when in the programme screen If P3 is already selected press the time button to scroll through P1 P2 and back ...

Страница 9: ...day of week Whilst going through the functions this is a great time to set your comfort and economy temperatures Economy room unoccupied Comfort room occupied Tip Write down required times and modes before starting Before we set the programme we must set the clock When we programme we set the times for the comfort and economy modes to be in operation Setting the mode s temperature is done seperate...

Страница 10: ...ration Mode The operation mode can be selected using the mode button these are the same as those on the radiator and have the same function unless specified below Comfort and Economy Temperature Setting To set the temperature for both the comfort and economy modes select the desired mode using the mode button and set the temperature using the or buttons The economy temperature can never be set hig...

Страница 11: ...on press both the mode and buttons together for 3 seconds To disable the function repeat the same procedure 2 Hour Boost This mode will force continued heating for 2 hours independent of room temperature after this time the Richmond the radiator will enter the standby mode automatically When the radiator is turned on again it will enter the programme mode To select this press the 2 Hour Boost butt...

Страница 12: ...g this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local Civic Office your household waste ...

Отзывы: