10
Note:
• Cooling capacities are based on outdoor air temperature of 35
°
C Dry Bulb with controlled water inlet temperature of 12
°
C and
water outlet temperature of 7
°
C.
• Heating capacities are based on outdoor air temperature of 7
°
C Dry Bulb (44.6
°
F Dry Bulb), 6
°
C Wet Bulb (42.8
°
F Wet Bulb) with
controlled water inlet temperature of 30
°
C and water outlet temperature of 35
°
C.
• Specification are subjected to change without prior notice for further improvement.
Maximum Current For Monobloc Unit
A
25.0
Maximum Current For Internal Heater
(Back-up Tank Heater)
A
26 (39)
Power Factor
%
Cooling: 97
Heating: 96
Power factor means total figure of compressor and fan motor.
Power Cord
Number of core
-
Length
m (ft)
-
Thermostat
Electronic Control
Protection Device
Electronic Control
Item
Unit
Water System
Performance Test Condition
EUROVENT
Operation Range
Outdoor Ambient
°
C
Cooling: 16 ~ 43
Heating: -20 ~ 35
Water Outlet
°
C
Cooling: 5 ~ 20
Heating: 25 ~ 55
Internal Pressure Differential
kPa
Cooling: 25.0
Heating: 36.0
Refrigerant Pipe Diameter
Liquid
mm (inch)
9.52 (3/8)
Gas
mm (inch)
15.88 (5/8)
Water Pipe Diameter
Inlet
mm (inch)
30 (1-3/16)
Outlet
mm (inch)
30 (1-3/16)
Water Drain Hose Inner Diameter
mm (inch)
15.00 (19/32)
Pump
Motor Type
Capacitor Run Induction Motor (5
μ
F)
No. of Speed
3
Input Power
W
190
Hot Water Coil
Type
Brazed Plate
No. of Plates
60
Size (H x W x L)
mm
100
×
93
×
325
Water Flow Rate
l/min (m
3
/h)
Cooling: 33.0 (2.0)
Heating: 40.1 (2.4)
Pressure Relief Valve Water Circuit
kPa
Open: 190, Close: 186 and below
Flow Switch
Magnetic Lead Switch
Protection Device
A
Residual Current Circuit Breaker (40)
Expansion Vessel
Volume
I
10
MWP
bar
1
Capacity of Integrated Electric Heater
kW
6.00
Item
Unit
Monobloc Unit
Содержание WH-MDC09C3E5
Страница 14: ...14 4 Location of Controls and Components 4 1 Monobloc Unit ...
Страница 17: ...17 ...
Страница 18: ...18 ...
Страница 19: ...19 4 1 2 2 Weekly Timer Setting ...
Страница 20: ...20 4 1 2 3 Setting Up The Special Functions ...
Страница 21: ...21 5 Dimensions 5 1 Monobloc Unit ...
Страница 22: ...22 6 Refrigeration And Water Cycle Diagram ...
Страница 23: ...23 ...
Страница 24: ...24 7 Block Diagram 7 1 WH MDC09C3E5 ...
Страница 25: ...25 7 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 26: ...26 8 Wiring Connection Diagram 8 1 WH MDC09C3E5 ...
Страница 27: ...27 ...
Страница 28: ...28 8 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 29: ...29 ...
Страница 30: ...30 9 Electronic Circuit Diagram 9 1 WH MDC09C3E5 ...
Страница 31: ...31 ...
Страница 32: ...32 9 2 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 ...
Страница 33: ...33 ...
Страница 34: ...34 10 Printed Circuit Board 10 1 Water System 10 1 1 Main Printed Circuit Board ...
Страница 35: ...35 10 1 2 Solar Printed Circuit Board Optional ...
Страница 36: ...36 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Страница 37: ...37 10 2 2 Capacitor Printed Circuit Board 10 2 3 Noise Filter Printed Circuit Board ...
Страница 38: ...38 11 Installation Instruction Monobloc Unit Dimension Diagram ...
Страница 39: ...39 Main Components ...
Страница 52: ...52 Solar Priority is Set Solar Priority is Not Set ...
Страница 55: ...55 Heat Tank Heating No Priority Solar Priority Set ...
Страница 56: ...56 Heat Tank Heating No Priority Solar Priority Not Set ...
Страница 66: ...66 Solar Priority Not Set Heat Tank Mode Heating Priority Set ...
Страница 67: ...67 Tank Mode Solar Priority Set Solar Priority Not Set ...
Страница 115: ...115 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Страница 118: ...118 17 10 To Remove Bottle Complete When reinstall the water pipe use grease or water at the joining ...
Страница 130: ...130 ...
Страница 134: ...134 19 2 WH MDC09C3E5 WH MDC12C6E5 WH MDC14C6E5 WH MDC16C6E5 Water System ...