Programming
40
Functions of the camera (optional)
The functions listed below can be set when selecting “CAMERA” (main monitor station) or “CAM” (sub monitor station) in step
2 on page 38. You can set the functions of the camera 1 – 4 separately.
The default setting is indicated in bolds.
[ ]: Function names when using the sub monitor station.
Functions
Contents
CAMERA RINGER
[CAM RINGER]
You can select the ringer pattern that is heard from the camera when the sensor
detects motion.
TONE A
, TONE B, TONE C, TONE D
L�
To confirm the ringer pattern, press
{
►
}
while selecting the desired tone.
CAMERA RINGER VOLUME
[CAM RINGER VOL]
You can select the volume of the camera ringer heard when the sensor detects motion.
HIGH,
MEDIUM
, LOW, OFF
SENSOR TYPE
[SENSOR TYPE]
You can select the sensor type (INTERNAL/EXTERNAL/OFF), the interval for detecting
motion (60 SEC/20 SEC/ALWAYS) and the activation of the auto recording feature
(ON/OFF).
INTERNAL (60 SEC AUTO REC ON)
[IN / 60 SEC AUTO REC ON]
,
INTERNAL (60 SEC AUTO REC OFF)
[IN / 60 SEC AUTO REC OFF],
INTERNAL (20 SEC AUTO REC ON)
[IN / 20 SEC AUTO REC ON],
INTERNAL (20 SEC AUTO REC OFF)
[IN / 20 SEC AUTO REC OFF],
EXTERNAL (60 SEC AUTO REC ON)
[EXT / 60 SEC AUTO REC ON],
EXTERNAL (60 SEC AUTO REC OFF)
[EXT / 60 SEC AUTO REC OFF],
EXTERNAL (20 SEC AUTO REC ON)
[EXT / 20 SEC AUTO REC ON],
EXTERNAL (20 SEC AUTO REC OFF)
[EXT / 20 SEC AUTO REC OFF],
EXTERNAL (ALWAYS / AUTO REC OFF) [EXT / ALWAYS AUTO REC OFF],
OFF [OFF]
L�
When using a device connected to the external sensor terminal, select “EXTERNAL”.
INTERNAL SENSOR
SENSITIVITY
[IN SENSOR SENSITIVITY]
You can select the sensitivity of the sensor.
(For information about the sensor, refer to the Operating Instructions included with the
camera.)
NORMAL
, LOW
L�
The front detection distance is about 5 m when “NORMAL” is selected, and about
2 m when “LOW” is selected. (Surrounding temperature: Approx. 20 °C)
L�
When the sensor detects motion excessively, select “LOW”.
CAMERA MIC SENSITIVITY
[MIC SENSITIVITY]
You can select the microphone sensitivity of the camera.
HIGH,
MEDIUM
, LOW, OFF
L�
When “OFF” is selected, you cannot hear the sound from the camera.
CAMERA RECEIVER VOLUME
[CAM RECEIVER VOL]
You can select the speaker volume heard from the camera during the conversation
with a main monitor station user or sub monitor station user.
HIGH
, MEDIUM, LOW
IN USE INDICATOR
[IN USE INDICATOR]
Select “ALWAYS” to turn on the IN USE indicator on the camera at all times, “WHEN
CONNECTED” (main monitor station) or “CONNECTED” (sub monitor station) to turn
on the indicator only when the camera is in use, or “OFF” to turn off the indicator at all
times.
ALWAYS
, WHEN CONNECTED [CONNECTED], OFF
ZOOM
[ZOOM]
You can select whether the image from the camera is zooming in or not.
NORMAL
, ENLARGE (Approx. 1.6 x zoom)
EXPOSURE
[EXPOSURE]
The image quality is adjusted according to the exposure setting when the camera is in
dark environments. You can select the following exposure levels.
(Darker) -3, -2, -1,
0
(NORMAL)
, +1, +2, +3 (Brighter)
REVERSE PICTURES
[REVERSE PICS]
You can select whether the image from the camera is upside down or not.
YES,
NO
INITIALIZATION SETTINGS
[INIT SETTINGS]
This feature resets all settings of the camera to their default settings.
YES, NO
VL-SW102BX_OI.indb 40