– 103 –
Chapter 9 Other Useful Functions — Setting the time data
Example of connections for external locking
As shown in the figure, connect both the reference video signal and the reference time code.
Reference time code
<GENLOCK IN> terminal
<TC IN/OUT> terminal
Reference video signal
External lock operation procedure
To externally lock the time code, follow the steps below.
1
Press the <TC> button to display the TC screen.
2
From the time code display, select [Free Run] in [Free/Rec].
3
From [MENU]
→
[REC SETTINGS]
→
[TC]
→
[TC IN/OUT SEL], select [TC IN].
4
Set [MENU]
→
[SYSTEM SETTINGS]
→
[GENLOCK]
→
[GENLOCK MODE] to [EXT] and synchronize to the genlock signal input.
5
Enter the external time code from the <TC IN/OUT> terminal.
The [TCG] characters on the HOME screen are displayed in black and white inversion.
f
Input the same SDI signal as the system signal format ([FREQUENCY]) for the reference video signal.
f
When the system frequency is 59.94p or 50p, the time code may be out of sync by one field.
To externally lock without shifting the time code at this time, input the 59.94i signal for when system frequency is [59.94p], or 50.00i signal for
[50.00i] into the <GENLOCK IN> terminal. Input the synchronized time code signal from the <TC IN/OUT> terminal to there.
f
When the input reference signal of generator lock is disrupted, recording cannot be performed normally. [TEMPORARY PAUSE] is displayed in the
viewfinder screen, and the clip is divided. The synchronization with the time code is also not guaranteed. Recording will resume when the signal
returns to normal.
f
The time code is instantly locked to the external time code, and the same value as the external time code value is displayed in the time code
display area when the external lock operation is performed. Do not set to the recording mode for several seconds until the internal system lock has
stabilized. Furthermore, lock the time code to the <TC IN/OUT> terminal signal.
f
If you execute the slave once, even if there is no longer <TC IN/OUT> terminal and <GENLOCK IN> terminal input, the slave status is maintained.
However, in the following cases, the slave status will be released.
-
When [TC SET] is executed
-
When the power is turned off
-
When switched [DF]/[NDF]
-
When set to [Rec Run]
-
When a variable frame rate is applied
f
If [EXT INPUT] is selected in [UB MODE] of the UB screen, regardless of the time code slave status, the user bits can be matched with the user
bits input in the <TC IN/OUT> terminal. In this case, [UBG] characters are black and white inverted.
Cautions when switching the power supply from the battery to the external power supply while an external lock is
active
To maintain the continuity of the power supply for the time code generator, connect an external power supply to the <DC IN> terminal, and disconnect
the battery in the battery holder after confirming the battery information of the <DC IN> terminal side is displayed in the viewfinder or the HOME screen.
If the battery pack is removed first, there is no guarantee that the time code will stay externally locked.
Содержание VARICAM LT
Страница 1: ...LT Operating Guide Version 1 W0316HM0 YI VQT5M58A E The photograph is an example of a system ...
Страница 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Страница 83: ...This chapter describes the viewfinder screen display and how to make adjustments Chapter 7 Viewfinder ...
Страница 91: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Страница 94: ...This chapter describes other useful features such as function buttons etc Chapter 9 Other Useful Functions ...
Страница 155: ...This chapter describes how to use the camera by connecting to network Chapter 11 Network Connection ...
Страница 169: ...This chapter describes the maintenance method and warning system of the camera Chapter 12 Maintenance ...
Страница 175: ...This chapter describes the specifications of this product Chapter 13 Specification ...
Страница 182: ...Web Site http www panasonic com Panasonic Corporation 2016 ...