93
English
Command transmission method
Transmit in the following command format
Transmitted data
Header
Control
symbol Data part
Control
symbol
Last
terminal
symbol
Hash value
(see
“Connection
method”)
(STX)
0x02
Control
command
(ASCII
character
string)
(ETX)
0x03
(CR)
0x0d
32 bytes
1 byte Undefined 1 byte
1 byte
Received data
Control
symbol
Data part
Control
symbol
Last
terminal
symbol
(STX)
0x02
Control
command
(ASCII
character
string)
(ETX)
0x03
(CR)
0x0d
1 byte
Undefined
1 byte
1 byte
Error response
Error message
Last
terminal
symbol
“ERR1”
: Undefined control
command
(CR)
0x0d
“ERR2”
: Out of parameter range
“ERR3”
: Busy status or reception
invalid period
“ERR4”
: Timeout or reception
invalid period
“ERR5”
: Wrong data length
“PDPCONTROL
ERRA”
: Mismatching of
password
4 bytes or 15 bytes
1 byte
2. When [LAN control protocol] is set
to [Protocol 2].
Communicates with the same protocol as that of a
Panasonic projector
Connection method
1
Obtain the display’s IP address and the port number
(Default is 1024), and request connection to the
display.
The IP address and the port number can be obtained
from the following menus.
•
IP address:
[Setup
] → [
Network settings
] → [
LAN setup] or
[Network status]
•
Port number:
[Setup
] → [
Network settings
] → [
LAN setup]
●
For more detail of the settings, see page 75.
2
The display responds.
Response data
Data part Space Mode Space
Random
number
part
Last
terminal
symbol
[NTCONTROL]
(ASCII
character
string)
[ ]
0x20
[1]
0x31
[ ]
0x20
[zzzzzzzz]
(ASCII
code
hex
number)
(CR)
0x0d
9 bytes
1 byte 1 byte 1 byte 8 bytes 1 byte
3
Hash the following data with the MD5 algorithm, and
generate a 32-byte hash value.
[xxxxxx:yyyyy:zzzzzzzz]
xxxxxx :
User name set for [Administrator account settings]
yyyyy :
Password set for the above [Administrator
account settings]
zzzzzzzz :
8-byte random number obtained in step 2