Alarm Settings
Programming Reference
4-24
DBS-EX23-530
Revised April 2000
Parameter
Loss of Signal Counter
Description
Determines how many instances of loss of signal occur before a
Signal Loss FF key is lit.
The FF key lights when the counter exceeds the specified number
within a 24-hour period.
(See page 4-35 for instructions on programming ISDN FF keys.)
Programming
Master cabinet: FF1 9# 4# 4# 3# 4# (0-9000)#
Slave cabinet: FF1 9# 4# 5# 3# 4# (0-9000)#
Options
0-9000
/
24 hours
(9000)
Parameter
Sync Loss Counter
Description
Determines how many instances of sync loss occur before a Sync
Loss FF key is lit.
The FF key lights when the counter exceeds the specified number
within a 24-hour period.
(See page 4-35 for instructions on programming FF alarm keys.)
Programming
Master cabinet: FF1 9# 4# 4# 3# 5# (0-9000)#
Slave cabinet: FF1 9# 4# 5# 3# 5# (0-9000)#
Options
0-9000
/
24 hours
(9000)
Parameter
Yellow Alarm Counter
Description
Determines how many yellow alarm indications occur before a
Yellow Alarm FF key is lit.
The FF key lights activated when the counter exceeds the specified
number within a 24-hour period.
(See page 4-35 for instructions on programming FF alarm keys.)
Programming
Master cabinet: FF1 9# 4# 4# 3# 6# (0-9000)#
Slave cabinet: FF1 9# 4# 5# 3# 6# (0-9000)#
Options
0-9000/24 hours
(9000)
Содержание T-SMART DBS-EX23-530
Страница 8: ...viii DBS EX23 530 Revised April 2000 ...
Страница 10: ...1 2 DBS EX23 530 Revised April 2000 ...
Страница 18: ...Pre Installation Requirements Introduction to the ISDN Interface 1 10 DBS EX23 530 April 2000 ...
Страница 20: ...2 2 DBS EX22 530 Revised April 2000 ...
Страница 44: ...3 2 DBS EX23 530 Revised April 2000 ...
Страница 54: ...4 2 DBS EX23 530 Revised April 2000 ...