Digital Pad Settings
Programming Reference
4-14
DBS-EX23-530
Revised April 2000
Extension Port Settings
Parameter
Station Port Class
Description
By default, DBS phones are assigned a circuit type, based on
whether they are KTELs or SLTs.
The circuit type is used with digital pad settings to determine the
loss/gain settings for connections to the ISDN. (See “Digital Pad
Setting” on page 4-12.)
The Port Class parameter is provided in case a specific phone or
group of phones needs a unique pad level.
For example, an SLT is assigned by default as “circuit type 2.” How-
ever, if an SLT in a remote warehouse has inadequate volume levels,
the circuit type for the SLT could be changed to 7 (Option 1). Once
the SLT is changed to circuit type 7, the pad levels for circuit type 7
could be changed to provide the correct volume setting.
Note:
Circuit types are also provided for trunk ports. See Figure 4-1
on page 4-12 for a definition of circuit types.
Programming
FF3 (1-144)# 37# (1-2 or 7-8)#
Options
This programming parameter will allow you to assign circuit types
1-12 to a station port. However, the only circuit types that should be
used with a station port are circuit types 1, 2, 7, or 8. (Circuit types 7
and 8 are used to assign unique PAD levels to circuits that require
special volume levels.)
Содержание T-SMART DBS-EX23-530
Страница 8: ...viii DBS EX23 530 Revised April 2000 ...
Страница 10: ...1 2 DBS EX23 530 Revised April 2000 ...
Страница 18: ...Pre Installation Requirements Introduction to the ISDN Interface 1 10 DBS EX23 530 April 2000 ...
Страница 20: ...2 2 DBS EX22 530 Revised April 2000 ...
Страница 44: ...3 2 DBS EX23 530 Revised April 2000 ...
Страница 54: ...4 2 DBS EX23 530 Revised April 2000 ...