Parameter
Multiple DID/DNIS
Description
This programming address controls two functions.
If only analog trunks are used, a “1” turns on multiple DID num-
bering. Multiple DID numbering allows the assignment of one
DID number to multiple extensions. If one DID number is
assigned to multiple stations, the stations ring simultaneously
when the DID number is dialed. More than one DID number can
be assigned to a single extension.
If ISDN trunks are used, a “1” also turns on multiple Inbound
ISDN DID numbering. Multiple Inbound DNIS numbering allows
the assignment of one ISDN DID number to multiple extensions.
If one ISDN DID number is assigned to multiple stations, the sta-
tions ring simultaneously when the DID number is dialed. More
than one DID number can be assigned to a single extension.
Up to 500 DID numbers can be assigned in each system; also, up to
500 Inbound ISDN DID numbers can be assigned. When Inbound
ISDN DID numbering is used, both the Inbound DID number table
and the DID table are used. See “Inbound ISDN DID Assignment”
on page 4-29 for more information on assigning DNIS numbers.
Programming
FF1 2# 1# 32# (0-1)#
Options
0=Off
1=On
Содержание T-SMART DBS-EX23-530
Страница 8: ...viii DBS EX23 530 Revised April 2000 ...
Страница 10: ...1 2 DBS EX23 530 Revised April 2000 ...
Страница 18: ...Pre Installation Requirements Introduction to the ISDN Interface 1 10 DBS EX23 530 April 2000 ...
Страница 20: ...2 2 DBS EX22 530 Revised April 2000 ...
Страница 44: ...3 2 DBS EX23 530 Revised April 2000 ...
Страница 54: ...4 2 DBS EX23 530 Revised April 2000 ...