Special ISDN Function Codes
Programming Reference
4-38
DBS-EX23-530
Revised April 2000
Parameter
Forced Re-synchronization
Description
Re-synchronizes the DBS ISDN with the public network.
Notes:
1. Forced re-synchronization disconnects existing calls.
2. Before executing this code, you must first enter the program-
ming authorization code (#98 9999).
Execution
Master: ON/OFF #94 6
Slave: ON/OFF #95 6
Options
None. Re-synchronization begins as soon as the code is entered.
Parameter
Historical Error Clearance
Description
Clears the error counters for the following alarms:
• yellow
• red
• framing
loss
• slip
rate
• loss of signal
• sync
loss
Note:
Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Execution
Master: ON/OFF #94 7
Slave: ON/OFF #95 7
Options
None. The counters are cleared as soon as the code is entered.
Parameter
Alarm Relay Clear
Description
Clears (opens) the alarm relay on the ISDN MDF card.
Note:
Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Execution
Master: ON/OFF #94 8
Slave: ON/OFF #95 8
Options
None. The relay is cleared as soon as the code is entered.
Содержание T-SMART DBS-EX23-530
Страница 8: ...viii DBS EX23 530 Revised April 2000 ...
Страница 10: ...1 2 DBS EX23 530 Revised April 2000 ...
Страница 18: ...Pre Installation Requirements Introduction to the ISDN Interface 1 10 DBS EX23 530 April 2000 ...
Страница 20: ...2 2 DBS EX22 530 Revised April 2000 ...
Страница 44: ...3 2 DBS EX23 530 Revised April 2000 ...
Страница 54: ...4 2 DBS EX23 530 Revised April 2000 ...