Programming Reference
Alarm Settings
Revised April 2000
DBS-EX23-530
4-27
Parameter
Relay Reset
Description
Determines whether the ISDN alarm relay is cleared (opened) auto-
matically or manually.
If cleared automatically, the relay is opened approximately one sec-
ond after the alarm condition ceases.
If cleared manually, the relay can be opened by entering the Alarm
Relay Clear code.
To enter the Alarm Relay Clear code, first enter the programming
authorization code (#98 9999), then enter one of the following
codes:
(Master cabinet: ON/OFF #94 8)
(Slave cabinet: ON/OFF #95 8)
Programming
Master cabinet: FF1 9# 4# 4# 4# 6# (0-1)#
Slave cabinet: FF1 9# 4# 5# 4# 6# (0-1)#
Options
0=Auto
1=Manual