SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
29/184
Labels To Be Used
■ Input labels
Name
Variable name
Data type
Valid range
Description
Execution Command
i_bEN
Bit
ON, OFF
Turn ON this label to start the
FB. You can exit from the FB by
turning it from ON to OFF.
CC-Link IE Field flag
i_bIeFieldFlag
Bit
ON, OFF
Turn ON Execution Command
(i_bEN) with this flag OFF to
start the FB on SC-HG1-C or
with this flag ON to start the FB
on SC-HG1-CEF.
Start I/O No.
i_uStartIONo
Word
[Unsigned]
Depends on the range of
the number of input/output
points of the target CPU
module. For more
information, refer to the
CPU User's Manual.
Specify in hexadecimal the
number of the starting I/O where
the target CC-Link/CC-Link IE
Field master/local module is
installed. (For example, specify
H0A0 if the starting I/O No. is
00A0.)
Station No.
i_uStationNo
Word
[Unsigned]
1 to 64 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is OFF
1 to 120 (in decimal)
when CC-Link IE Field
Flag (i_bIeFieldFlag) is
ON
Specify the station number of the
communication unit you want to
configure.
Response Data
i_uResponseData
Word
[Unsigned]
0 to 3
Select the data you want to output
to Detected Value
(o_d15DetectedValue).
0: Judgment value
1: Normal measurement value
2: Calculated value
3: Sensor head value