SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
108/184
Labels To Be Used
■ Input labels
Name
Variable name
Data type
Valid range
Description
Execution Command
i_bEN
Bit
ON, OFF
Turn ON this label to start the FB. You
can exit from the FB by turning it from
ON to OFF.
CC-Link IE Field flag
i_bIeFieldFlag Bit
ON, OFF
Turn ON Execution Command (i_bEN)
with this flag OFF to start the FB on
SC-HG1-C or with this flag ON to start
the FB on SC-HG1-CEF.
Start I/O No.
i_uStartIONo
Word
[Unsigned]
Depends on the range of
the number of input/output
points of the target CPU
module. For more
information, refer to the
CPU User's Manual.
Specify in hexadecimal the number of
the starting I/O where the target
CC-Link/CC-Link IE Field master/local
module is installed. (For example,
specify H0A0 if the starting I/O No. is
00A0.)
Station No.
i_uStationNo
Word
[Unsigned]
1 to 64 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is OFF
1 to 120 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is ON
Specify the station number of the
communication unit you want to
configure.
Set Controller
i_uSetController
Word
[Unsigned]
16-bit data other than 0
Stores the word information (consisting
of 16 pieces of bit information) that
corresponds to the controller on which to
execute the command.
bit 0: Master device
bit 1: 1st slave device
to
bit 13: 13th slave device
bit 14: 14th slave device
bit 15: OFF (Not used)
Load Flag
i_bLoadFlag
Bit
ON, OFF
When started with this flag ON, the FB
loads data bank.
When started with this flag OFF, the FB
saves data bank.
Data Bank No.
i_uDataBankNo
Word
[Unsigned]
1 to 3
Specify the data bank number.