SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
49/184
Labels To Be Used
■ Input labels
Name
Variable name
Data type
Valid range
Description
Execution Command
i_bEN
Bit
ON, OFF
Turn ON this label to start the FB.
You can exit from the FB by
turning it from ON to OFF.
CC-Link IE Field flag
i_bIeFieldFlag
Bit
ON, OFF
Turn ON Execution Command
(i_bEN) with this flag OFF to start
the FB on SC-HG1-C or with this
flag ON to start the FB on
SC-HG1-CEF.
Start I/O No.
i_uStartIONo
Word
[Unsigned]
Depends on the range of the
number of input/output points
of the target CPU module. For
more information, refer to the
CPU User's Manual.
Specify in hexadecimal the number
of the starting I/O where the target
CC-Link/CC-Link IE Field
master/local module is installed.
(For example, specify H0A0 if the
starting I/O No. is 00A0.)
Station No.
i_uStationNo
Word
[Unsigned]
1 to 64 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is OFF
1 to 120 (in decimal) when
CC-Link IE Field Flag
(i_bIeFieldFlag) is ON
Specify the station number of the
communication unit you want to
configure.
Set Controller
i_uSetController
Word
[Unsigned]
16-bit data other than 0
Stores the word information
(consisting of 16 pieces of bit
information) that corresponds to
the controller on which to execute
the command.
bit 0: Master device
bit 1: 1st slave device
to
bit 13: 13th slave device
bit 14: 14th slave device
bit 15: OFF (Not used)