SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
105/184
Item
Description
Description of
functions
When Execution Command (i_bEN) is turned ON on the controller specified by Set Controller
(i_uSetController), this FB saves the setting value to the data bank identified by the value of Data
Bank No. (i_uDataBankNo) if Load Flag (i_bLoadFlag) is OFF or, if Load Flag (i_bLoadFlag) is
ON, loads the data bank identified by the value Data Bank No. (i_uDataBankNo).
FB compilation
method
Macro type
FB behavior
Pulse execution type (multi-scan execution type)
i_bEN input condition None
I/O signal flow
movement
[Normal completion]
[Error completion]
If an FB error occurs:
If Execution Command (i_bEN) is turned from
ON to OFF before Normal Completion (o_bOK)
or Error Completion (o_bErr) turns ON:
If a module error occurs: