SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
WUME-SCHG1IQRFB-1
159/184
Appendix 2.4.
Module Error Code (o_ud16 ModuleErrId) list
Some FBs in this FB library return an error code to Module Error Code (o_u16ModuleErrId) when a module error occurs
(with o_uErrId being a hexadecimal value of "FFFF"). Module error codes that may be output are listed below.
Error Code
Hexadecimal
(Decimal)
Description
Meaning
Cont
rol
le
r ope
ra
tion r
el
at
ed
er
ror
c
ode
s
64
(100)
A command not included in the command list was
received.
Enter the correct command.
65
(101)
A setting parameter outside the valid range was
received.
Enter a valid parameter.
66
(102)
Write was requested with settings not supported by
the target controller.
Enter a valid parameter.
190
(400)
Calibration was attempted with no alarm specified
or the display range exceeded.
The head value is invalid. Check the head status.
191
(401)
Calibration was not correctly performed.
Calibration failed.
For information on the calibration procedure, refer to
"Contact-Type Digital Displacement Sensor HG-S
Series User's Manual ".
1F4
(500)
Teaching was attempted with no alarm specified or
the display range exceeded.
The head value is invalid. Check the head status.
1F5
(501)
Teaching was not performed.
Teaching failed.
For information on the teaching procedure, refer to
"Contact-Type Digital Displacement Sensor HG-S
Series User's Manual ".
258
(600)
Presetting was attempted with no alarm specified or
the display range exceeded.
The head value is invalid. Check the head status.
2BC
(700)
Bank loading or saving was attempted with the bank
number outside the valid range.
Enter a valid parameter.
320
(800)
Failed to write to EEPROM.
The controller may be faulty.
Check the controller status.
384
(900)
Controller did not respond within 100 ms of a
command request.
Check the controller connection status. Check for
faulty controllers.