83
Available commands are listed below.
S
Set whether the power supply is enabled or disabled.
1. Press "S." The command prompt changes to "Select port number to be changed>." Enter
a port number you wish to configure. (To configure all ports at once, enter "0" as the
port number.)
2. Then, the command prompt changes to "Up or Down PoE port admin status (U/D)>."
Press "U" to enable power supply (Up). Press "D" to disable it (Down).
L
Set the upper limit of power supply.
1. Press "L." The command prompt changes to "Select port number to be changed>." Enter
a port number you wish to configure. (To configure all ports at once, enter "0" as the
port number.)
2. Then, the command prompt changes to "Enter the power limit>." Enter the limit
between 3000 and 15400 mW (in units of 200 mW).
Q
Return to the parent menu.
Note:
If power request exceeds the limit of the whole unit, a port with a larger port
number is blocked to stop supplying power.