Chapter 4
Settings — [SIGNAL LIST] menu
ENGLISH - 129
f
To cancel the deletion, press the <MENU> button to return to the
[REGISTERED SIGNAL LIST]
screen.
3) Press the <ENTER> button.
f
The selected signal will be deleted.
Note
f
A registered signal can also be deleted from [REGISTERED SIGNAL DELETE] on the
[REGISTERED SIGNAL SETUP]
screen.
Protecting the registered signal
1) Press
asqw
to select the signal to protect.
2) Press the <ENTER> button.
f
The
[REGISTERED SIGNAL STATUS]
screen is displayed.
3) Press the <ENTER> button.
f
The
[REGISTERED SIGNAL SETUP]
screen is displayed.
4) Press
as
to select [LOCK].
5) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
The signal is not protected.
[ON]
The signal is protected.
Note
f
When [LOCK] is set to [ON], signal deletion, image adjustment, and automatic setup are not available. To perform these operations, set
[LOCK] to [OFF].
f
A signal can be registered to the sub memory even if it is protected.
f
Even a protected signal will be deleted if [INITIALIZE] is executed.
Expanding signal lock-in range
1) Press
asqw
to select the signal to set.
2) Press the <ENTER> button.
f
The
[REGISTERED SIGNAL STATUS]
screen is displayed.
3) Press the <ENTER> button.
f
The
[REGISTERED SIGNAL SETUP]
screen is displayed.
4) Press
as
to select [LOCK-IN RANGE].
5) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[NARROW]
Select in most cases.
[WIDE]
Widens the lock-in range.
Note
f
Switch the range that determines that a signal to be input is the same signal that is already registered.
f
To prioritize the determination that it is the same signal that is already registered, set to the [WIDE] setting.
f
Use in cases such as when the synchronizing frequency of a signal to be input has changed slightly, or multiple signal lists are registered.
f
Can only be used when a signal is input from the <RGB 1 IN> terminal, <RGB 2 IN> terminal, <DVI-D IN> terminal, or <HDMI IN> terminal.
f
When [WIDE] is set, the image may appear distorted because a signal is determined to be the same signal even if a synchronizing
frequency changes slightly.
f
When a signal to be input corresponds to multiple signals set in [WIDE], a registered signal with a high memory number receives priority.
Example: a signal to be input that corresponds to memory numbers A2, A4 and B1 will be determined to be B1.
f
When a registration signal is deleted, the settings are also deleted.
f
In an environment where multiple types of signals are input to the same terminal, signals are sometimes not determined correctly when the
setting is set to [WIDE].