Chapter 4
Settings — [PROJECTOR SETUP] menu
112 - ENGLISH
5) Press
as
to select [MODE].
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
Automatically corrects screen brightness when lamp brightness changes.
[PC]
Synchronizes nine or more projectors through a computer using the dedicated software “Multi
Projector Monitoring & Control Software”
*1
.
*1
“Multi Projector Monitoring & Control Software” is included in the supplied CD-ROM.
f
When [AUTO] is selected, proceed to Step
7)
.
7) Press
as
to select [LINK].
8) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Performs corrections by the brightness sensor in one projector without synchronizing with the other
projectors.
The period, in which the constant brightness kept by the small value of [BRIGHTNESS CONTROL
GAIN], is prolonged.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Synchronizes corrections in multiple projectors by the brightness sensor.
You can set up to four groups (A to D) within the same subnet by using the network function.
You can also register and synchronize up to eight projectors in one group.
9) Press
as
to select [CALIBRATION TIME].
10) Press the <ENTER> button.
f
Enters adjustment mode (the display is blinking).
11) Press
qw
to select “hour” or “minute”, and press
as
or the number (<0> - <9>) buttons to set a
time.
f
Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows setting of only the minute in
increments of one minute between 00 and 59.
f
If you do not specify the time, select [OFF] between 23 and 00 o’clock or between 59 and 00 minutes.
12) Press the <ENTER> button.
f
[CALIBRATION TIME] is set.
f
Brightness is measured at the specified time. Dynamic iris is fixed to open during measurement.
13) Press
as
to select [CALIBRATION MESSAGE].
14) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[ON]
Messages are displayed during calibration.
[OFF]
Messages are not displayed during calibration.
15) Press
as
to select [APPLY].
16) Press the <ENTER> button.
f
The set [MODE] and [LINK] are enabled, and LAMP RELAY screen alert is displayed when the [LAMP RELAY] setting is [OFF]. When
[CALIBRATION MESSAGE] is set to [ON], a calibration running message is displayed which will automatically disappear 30 seconds
after calibration completes.
f
If the <ENTER> button is pressed with [MODE] in [BRIGHTNESS CONTROL SETUP] set to other than [OFF], the brightness of the
lamp at the time the button was pressed is recorded as the standard brightness.
f
If the <ENTER> button is pressed when [LINK] is set from [GROUP A] to [GROUP D], the group name is displayed on the screens of
projectors that have been set in the same group.
LINK
GROUP A