SR-ZSV00039
-
3
-
Motor Business Unit, Appliances Company, Panasonic Corporation
Category
Signal
Code
Connector
pin No.
Item
Command scaling
switch 1
DIV1
-
This input switches the command scaling numerator.
For details, see Section 6-4.
Damping switch 1
VS-SEL1
-
This input switches frequencies applied for the damping control.
Together with the damping switch 2 (VS-SEL2), it is possible to
switch between four frequencies at the maximum.
For details, see Section 5-2-
4
.
Gain switch
GAIN
-
Digital input to switch the gains between the 1st and 2nd in the
servo loop.
For details, see Section 5-2-
2
.
Torque limit switch
TL-SEL
-
Digital input to switch between the 1st and 2nd torque limits.
For details, see Section 6-1.
Damping switch 2
VS-SEL2
-
This input switches frequencies applied for the damping control.
Together with the damping switch 1 (VS-SEL1), it is possible to
switch between four frequencies at the maximum.
For details, see Section 5-2-
4
.
Command scaling
switch 2
DIV2
This input switches the command scaling.
For details, see Section 6-
3
.
Cont
ro
l
in
put
Forced Alarm Input
E-STOP
Generates Err87.0 "Compulsory alarm input protection".
The "*" mark attached to pin numbers displays that functions of signals and logics can be altered among pins with number
Pr
4.00 -
Pr
4.0
5
(SI* input selection). Note that pin numbers assignable to the following functions cannot be changed.
Deviation Counter Clear Input (CL): SI
3
; Command Pulse Inhibition Input (INH): SI
4
No function is allocated to the connector pins marked with "-" in the default setting.