SR-ZSV00039
-
41
-
Motor Business Unit, Appliances Company, Panasonic Corporation
5
-
2
-
4
Damping Control
When an end of the equipment vibrates or the entire device shakes, damping control can be used to remove
the vibration frequency component from a position command for the reduction of vibration. Of the four
frequency settings, up to two can be used simultaneously.
Curr ent
c ontrol
Pos ition/veloc ity
c ontrol
Pos ition
command
Torque
command
Motor
c urrent
Motor
Encoder
Ser vo drive
Motor pos ition
Load
Anti-
vibration fil ter
モータ
カップリング
ボールねじ
薄い鉄の板
移動体
移動
変位センサで振動観測
先端が振動
機台
ドライバ
シーケンサ
End vibration frequency specifi ed
PLC
Coupling
Moving
object
Ball scr ew
Base
Vibration obs erve d with
displ acement sensor
End vibrates
1
)
Scope of applications
Damping control functions under the following conditions.
Conditions for the functioning of damping control
Action state
When sub-on,because the input instruction,lead the action shaking.
2
)
Cautions
Damping control may not function normally or may not be effective in the following conditions.
Conditions hindering the functioning of damping control
Load condition
Vibration is excited by a factor other than a command (external force, etc.).
The ratio of the resonance frequency to the antiresonance frequency is large.
The vibration frequency is out of the 1.0 - 200.0 [Hz] range.
For the frequency of vibration,the responsion of the position
control is low.