№
SR-ZSV00039
-
22
-
Motor Business Unit, Appliances Company, Panasonic Corporation
4
-
2
-
6
In-position Output (INP)
Whether or not positioning has been completed can be checked with the In-position output (INP). This signal is
turned on when the absolute value of the deviation counter value in position control is in the in-position range specified
with the parameter. Settings such as including in the criteria whether or not a position command has been given are
also available.
■
Related parameters
Category
No.
Parameter
Setup
range
Unit
Function
4
31
Positioning complete
(In-position) range
0
262144
Com-
mand
unit
Set the threshold of position deviation that outputs the in-position signal
(INP1).
The unit is command by default, but it can be changed to encoder in
Pr5.20 "Position setup unit select". Note that in that case, the unit of
Pr0.14 "Position deviation excess setup" is also changed.
4
32
Positioning complete
(In-position) output
setup
0
3
-
Selects a condition to output the in-position signal (INP1).
0: The signal turns ON when the position deviation does not exceed
Pr4.31 "Positioning complete (In-position) range".
1: The signal turns ON when there is no position command and the
position deviation does not exceed Pr4.31 "Positioning complete
(In-position) range".
2: The signal turns ON when there is no position command, the
zero-speed detection signal is ON, and the position deviation does
not exceed Pr4.31 "Positioning complete (In-position) range".
3: The signal turns ON when there is no position command and the
position deviation does not exceed Pr4.31 "Positioning complete
(In-position) range". Then, the signal remains turned ON until
Pr4.33 "INP hold time" is over. After "INP hold time" is over, the
INP output turns ON/OFF depending on the status of position
command or position deviation.
4
33
INP hold time
0
30000
1 ms
Set the hold time for Pr4.32 "Positioning complete (In-position) output
setup" being set as 3.
0:
The hold time is infinite and the ON status is maintained until
the next position command is given.
1 - 30000: The motor remains turned ON for the period set [ms]. Note
that the motor is turned OFF when a position command is
issued during the hold time.
4
42
2nd Positioning
complete (In-position)
range
0
262144
Comman
d unit
Set the threshold of position deviation that outputs the in-position signal
2 (INP2). INP2 turns ON whenever the position deviation does not
exceed the value set in this setting, regardless of Pr4.32 "Positioning
complete (In-position) output setup". (The presence/absence of a
position command is irrelevant.)
The unit is command by default, but it can be changed to encoder in
Pr5.20 "Position setup unit select". Note that in that case, the unit of
Pr0.14 "Position deviation excess setup" is also changed.
The presence/absence of a position command is judged by a command issued after the position command filter.
For the position command filter, see Section 4-2-3 "Position Command Filter."