Counter Clear (CL)
This function allows the position deviation counter value in position control to be cleared to 0 by using a deviation
counter clear input (CL).
■
Related parameters
Category
No.
Parameter
Setup range
Unit
Function
5
17
Counter clear input
mode
0
4
Selects the input mode of deviation counter clear input.
0: Invalid
1: Clear by level (without reading filter)
2: Clear by level (with reading filter)
3: Clear by edge (without reading filter)
4: Clear by edge (with reading filter)
For signal width and timing of deviation clear that need deviation counter clear input (CL), see the table below.
Pr5.17
CL signal
width
Timing of clearing deviation
1
500
s or
longer
2
1 ms min.
Continue to clear when the deviation counter clear input is ON*1.
3
100
s or
longer
4
1 ms min.
Clear once at the edge*1 where the deviation counter clear input turns
ON.
*1 The deviation counter clear input being OFF represents the input photocoupler being OFF, and the deviation
counter clear input being ON represents the input photocoupler being ON.