SR-ZSV00039
-
23
-
Motor Business Unit, Appliances Company, Panasonic Corporation
4
-
2
-
7
Command Pulse Inhibition (INH)
The command pulse inhibition input signal (INH) can be used to force the command pulse input processing to stop.
Turning the INH input on forces the servo drive to ignore the command pulse input and the pulse counting does not take
place.
This function is disabled by the factory setting. Before use, change the setting of Pr5.18 "Invalidation of command
pulse inhibit input".
Related parameters
Category
No.
Parameter
Setup
range
Unit
Function
5
18
Invalidation of com-
mand pulse inhibit input
0
1
Enables/disables the command pulse inhibition input.
0: Enable
1: Disable
5
19
Command pulse inhibit
input reading setup
0
4
Selects the cycle of reading the signal of command pulse inhibition
input. Updates the status of signal when it is periodically read and
found the same twice or more.
0: 0.166 ms
1: 0.333 ms
2: 1 ms
3: 1.666 ms
4: 0.166 ms (when the signal is found the same twice or more)
A prolonged cycle of reading decreases the likelihood of misoperation
caused by noise, but it also reduces responsiveness to signal input.