199
Description
5
Module H/W (Module Height/Width) :
Specifies the height and width of module which compose a symbol.
Setting Range
QR code: 0.050 to 1.000 mm
DataMatrix code: 0.001 to 1.000 mm
Reference
• If the size of module is same as or very smaller than that specified at “4-11 Laser Setting” (P.214), the module inside the
encode area may not be marked uniformly. In this case, enlarge the size of the module or narrow the line.
6
Code Data :
Specifies the data to be coded.
For input characters, refer to “Code Type and Code Data” (P.190).
When the code data is set in the several strings, they are connected together without linefeed to create the code
data. This linefeed can be applied only to the human readable text of the GS1 DataMatrix.
Reference
•
This product supports Format 06 (Macro 06) of ISO15434 for
DataMatrix.
•
For GS1 DataMatrix, the control code “FNC1” is automatically inputted
at the head of the code data. When inputting AI “01” followed by
13-digit numerical character, the check digit (modulus10/weight 3-1) is
inputted automatically at the next digit.
•
For DataMatrix, group separator (FNC1 or GS) of variable length AI
data is not inputted automatically.
Press the Symbol button on the Data Input screen and then press
FNC1 or GS on the Symbol Input screen.
In the standard, it is recommended to use FNC1 as the separator of
variable length AI data.
•
When the code data is set by the serial communication (RS-232C/Ethernet) command “BCS”, select “GS” or “FNC1”
as the separator of variable length AI data beforehand in “4-16-3 Communication, I/O Setting (Environment 3)” (P.261).
ME-LP400V-OP-6
Содержание LP-400 Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...