Valve

Air Hose

Quick Connect Plug

    (Nipple)

Gasket

    (1x replacement)

O-Ring 

(2x replacements)

INSTRUCTION MANUAL

AP-03

Model No.

Pneumatic Engraving Perforator

PICK-MARKER

COMPATIBLE MATERIALS

SAFETY PRECAUTIONS

Thank you for purchasing the Niigata Seiki Pneumatic Engraver.

Connected to an air compressor, the engraver is ideal for precision engraving work on a wide range of material, including 

molds and tooling, cutlery, glass, etc. Tool is also well suited for casting shakeout operations.

For safe and proper use of this product, please read this instruction manual before use and follow the procedures described. 

Please keep manual where it is accessible to user for future reference.

Keep this manual with the instrument if transferred or leased to a third party.

For inquiries about this product, please contact dealer or place of purchase.

Read this manual and follow the instructions.

Use of product other than as described in the manual 

may cause accident.

Use only for fine work on approved materials. 

Use other than as specified may cause product wear 

or damage, or a failure in an unpredictable manner.

Do not modify.

Modification of product may cause damage, accident, 

or injury. Do not modify under any circumstances.

Always wear work gloves.

Workpiece may fail while being engraved and cause 

injury.

Do not contact Stylus with skin or person.

Use care when handling as the Stylus is sharp.

Work piece should be firmly secured, and operator 

position should be stable. 

To insure that the Stylus does not slip and to avoid 

injury, make sure operator has a stable position and 

that workpiece is secure.

Handle with care.

Do not drop or subject to excessive shock. Do not 

place under heavy objects. Improper handling may 

cause damage.

Disconnect air supply to inspect or service 

instrument.

Always disconnect air supply when inspecting or replacing 

parts to prevent dangerous, unexpected operation.

PART IDENTIFICATION and FUNCTION

Stylus

Main Body

Collar

Engraving tip. 
This is a consumable item, please 
replace with new Stylus when worn.
Grip for holding the tool.
Supports the moving Stylus.
Lubricate with one (1) drop of oil 
daily.
Valve for turning on the 
compressed air to the engraver. 
Amount of air flow can also be 
adjusted.
Compressed air hose. 
Length:approx. 3m.
For connection to compressed air 
supply coupler. (Air compressor.)
Replacement internal parts for 
preventing air leaks.

Stylus

Main Body

Collar

Valve

Air Hose

Quick Connect Plug

    (Nipple) 

Gasket 

 O-Ring

Plastic

Glass

Non-Ferrous Metals

 Iron

Hardened Steel

Stainless Steel

・・・・・・・・・・・・・・・

・・・・・・・・・・・

・・・・・・・・・・・・・・・

・・・・・・・・・・・・・・・・

・・・・・・・・・・・・・

・・・

・・・・・

Tungsten Carbide

Materials listed as compatible may not give satisfactory results depending on surface treatment, thickness, etc. 

Always test material first in an inconspicuous area.

Always follow these marked operating procedures in order to prevent 

harm to yourself or others, and to prevent damage to property. 

Do not touch Stylus while connected to Air Supply.

When air is connected, Stylus moves very fast, over 

500 cycles/sec. Never touch the Stylus when air is 

connected.

Please Observe

CAUTION

Improper use may result in 

personal injury

 or damage to 

property

.

Denotes a prohibition- 
You 

MUST NOT do

Denotes a requirement- 
You 

MUST do

 Can be engraved

  

 Incompatible

Hardness HV510 or below

Отзывы: