Confirm that the Air Valve is OFF. 

(Figure:1)

If connection is made with Air Valve in the ON position, it may start to operate

unexpectedly.

Connect the Quick Connect Plug to the air supply.

Compressed air supply should be clean and dry. Make sure proper filter is 

connected to the compressor.

Unfiltered air may contain contamination which may cause malfunction or 

damage to the engraver.

Adjust the air compressor regulator to 0.7MPa.

Firmly hold the Air Valve and quickly rotate to ON position.

 (Figure:2)

Valve should be quickly turned to full ON position. The tool may not start if 

valve is turned slowly.

Position the Stylus perpendicular to the surface of the workpiece.

 

(Figure:3)

 Always test on inconspicuous area of the workpiece.

 Hold the Main Body of the tool near the tip.

The amount of air and the air pressure can be adjusted

 (0.4

0.7MPa).

 Air supply can be adjusted by rotating the Air Valve, and air pressure can be

 adjusted at the air compressor regulator. Monitor the engraving quality while

 making adjustments.

Apply one drop of lubricating oil daily to the tip 

where the Stylus meets the Main Body.

Keep out of reach of children, and store in a cool, dry, 

dark location.

Moisture and direct sunlight should be avoided, Please store 

in location secure from unauthorized use. 

Check for Stylus wear, and the condition of the 

internal Gasket and O-Ring.

The Stylus, Gasket, and O-Ring are consumable items and 

should be inspected regularly. Please replace with new ones 

if there are signs of wear.

Remove Cap by rotating in 
direction shown by the arrow.

Check the Gasket inside the 
Main body. If worn or 
damaged, remove using a 
pointed tool.

Peel the release paper from 
the new Gasket and affix to 
the inside of the Main Body.

Check the O-Ring inside the 
Cap. If worn or damaged, 
replace with a new O-Ring.

Remove the Stylus from the 
Cap and inspect for wear or 
damage. Replace as 
required.

Replacement Stylus sold 
separately, P/N...AP-PH3

OPERATION

AFTER USE CARE

STORAGE

Stylus does not vibrate properly.

If tool has not been used for long period the lubricating oil 

may be insufficient, or if the valve is opened slowly the 

Stylus may not start to move.

With Air Valve in ON position, give a slight shock to the 

Stylus to loosen.

Internal Gasket or O-ring may be worn. Disconnect Air 

supply, remove cap, are replace Gasket and O-ring.

If you continue to have problems after performing the above 

checks, contact your distributor or place of purchase.

FREQUENTLY ASKED QUESTIONS

SPECIFICATIONS

To operate, a separate air compressor is required to provide a supply of clean, compressed air.

Please prepare in accordance to the air compressor's instruction guide.

(Figure:1)

(Figure:2)

(Figure:3)

Perpendicular

ON

OFF

Valve

Valve

Workpiece

Refer to : After Use Care

Storage

Air Pressure Range

0.4

0.7MPa

Air Consumption

25

40L/min

Stylus Material

Carbide

Dimensions

  17

×

151mm

Air hose size

  4

×

6mm, 3m

Weight

250g (with air hose and coupler)

Stylus P/N

AP-PH3

I285-K   1601

Cap

Main 

Body

Main 

Body

Gasket

New 

Gasket

Cap

O-Ring

Cap

Stylus

Spring

Tool with pointed tip

Remove 

Remove 

Adhesive side