①
Confirm that the Air Valve is OFF.
(Figure:1)
・
If connection is made with Air Valve in the ON position, it may start to operate
unexpectedly.
②
Connect the Quick Connect Plug to the air supply.
・
Compressed air supply should be clean and dry. Make sure proper filter is
connected to the compressor.
Unfiltered air may contain contamination which may cause malfunction or
damage to the engraver.
③
Adjust the air compressor regulator to 0.7MPa.
④
Firmly hold the Air Valve and quickly rotate to ON position.
(Figure:2)
・
Valve should be quickly turned to full ON position. The tool may not start if
valve is turned slowly.
⑤
Position the Stylus perpendicular to the surface of the workpiece.
(Figure:3)
・
Always test on inconspicuous area of the workpiece.
・
Hold the Main Body of the tool near the tip.
⑥
The amount of air and the air pressure can be adjusted
(0.4
〜
0.7MPa).
・
Air supply can be adjusted by rotating the Air Valve, and air pressure can be
adjusted at the air compressor regulator. Monitor the engraving quality while
making adjustments.
●
Apply one drop of lubricating oil daily to the tip
where the Stylus meets the Main Body.
●
Keep out of reach of children, and store in a cool, dry,
dark location.
Moisture and direct sunlight should be avoided, Please store
in location secure from unauthorized use.
●
Check for Stylus wear, and the condition of the
internal Gasket and O-Ring.
The Stylus, Gasket, and O-Ring are consumable items and
should be inspected regularly. Please replace with new ones
if there are signs of wear.
①
Remove Cap by rotating in
direction shown by the arrow.
②
Check the Gasket inside the
Main body. If worn or
damaged, remove using a
pointed tool.
③
Peel the release paper from
the new Gasket and affix to
the inside of the Main Body.
④
Check the O-Ring inside the
Cap. If worn or damaged,
replace with a new O-Ring.
⑤
Remove the Stylus from the
Cap and inspect for wear or
damage. Replace as
required.
※
Replacement Stylus sold
separately, P/N...AP-PH3
OPERATION
AFTER USE CARE
・
STORAGE
●
Stylus does not vibrate properly.
⇒
If tool has not been used for long period the lubricating oil
may be insufficient, or if the valve is opened slowly the
Stylus may not start to move.
With Air Valve in ON position, give a slight shock to the
Stylus to loosen.
⇒
Internal Gasket or O-ring may be worn. Disconnect Air
supply, remove cap, are replace Gasket and O-ring.
※
If you continue to have problems after performing the above
checks, contact your distributor or place of purchase.
FREQUENTLY ASKED QUESTIONS
SPECIFICATIONS
To operate, a separate air compressor is required to provide a supply of clean, compressed air.
Please prepare in accordance to the air compressor's instruction guide.
(Figure:1)
(Figure:2)
(Figure:3)
Perpendicular
ON
OFF
Valve
Valve
Workpiece
Refer to : After Use Care
・
Storage
●
Air Pressure Range
:
0.4
〜
0.7MPa
●
Air Consumption
:
25
〜
40L/min
●
Stylus Material
:
Carbide
●
Dimensions
:
17
×
151mm
●
Air hose size
:
4
×
6mm, 3m
●
Weight
:
250g (with air hose and coupler)
●
Stylus P/N
:
AP-PH3
I285-K 1601
Cap
Main
Body
Main
Body
Gasket
New
Gasket
Cap
O-Ring
Cap
Stylus
Spring
Tool with pointed tip
Remove
Remove
Adhesive side