259
⿎
System Offset
This screen specifies the offset of marking position and laser power to the all registered files.
The functions are applicable to adjust the difference of laser power or displacement between laser marker and works in
case multiple production lines are used.
Item and Description
3
Laser Power :
Laser power offset. Offset the value of laser power set in each file.
Setting Range
50 to 200%
Reference
•
The laser power offset refers to the function to correct not the maximum laser power [W] value, but the laser power
setting value.
• “100” is specified if the value of “laser power (system offset)” × “laser power (laser setting)” is 100 or more.
4
Rotation Offset :
Rotates the object to the rotation direction around the original point.
Setting Range
-180.00 to +180.00 degree
+Y
-Y
+X
-X
Rotation (+) Rotation (-)
5
X/Y Offset :
Shifts the marking position to the X/Y direction.
Setting Range
-45.000 to +45.000 mm
(LP-V10)
-55.000 to +55.000 mm
(LP-430 / LP-420 / LP-410)
-80.000 to +80.000 mm
(LP-435 / LP-425 / LP-V15)
-27.500 to +27.500 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
6
X/Y Scale :
Sets the offset scale of marking field (X and Y). Area is corrected by inputting magnification.
Setting Range
70.000 to 130.000%
Reference
•
System offset is not offset on the image display.
• When marking data is inside of marking field on image display screen and the error “Existed marking data outside of
marking field” is displayed. Check the setting value in system offset.
ME-LP400V-OP-6
Содержание LP-400 Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...