4.9.4 Programming PS Ring Group
Overview of the PS Ring Group feature with SIP-CSs
SIP-CSs can provide the PS ring group feature. To use the feature, you must set the PS Ring Group setting
of the SIP-CS and the ICD group setting of the KX-NS1000.
A PS Ring Group of the SIP-CS is a group of S-PS extensions that receive the same incoming calls. Each PS
Ring Group has a floating extension number and name. The floating extension number is assigned to an ICD
group to be used for calling multiple S-PSs simultaneously.
One S-PS can belong to multiple PS Ring Groups.
Required settings for the KX-NS1000
Use Web Maintenance Console of the KX-NS1000 to program the following items.
•
Extension number setting:
Extension number must be assigned for all the SIP-CSs.
[Example]
SIP-CS
Ext. 300
SIP-CS
Ext. 302
SIP-CS
Ext. 301
•
ICD group setting:
All the extension numbers assigned to the SIP-CSs must be specified as members of an ICD group.
[Example]
Floating extension no.: 600
Members:
300, 301, 302
(Extension numbers of the SIP-CSs)
ICD Group 1
Floating extension no.: 601
Members:
300, 301, 302
(Extension numbers of the SIP-CSs)
ICD Group 2
Required settings for the SIP-CS
Use the Web user interface of the Super Master CS to program the following items.
•
PS Ring Group setting:
Create a PS Ring Group which contains the floating extension number of the ICD group that includes the
S-PSs to which you wish incoming calls to be broadcasted.
58
Installation Guide
4 Deployment Procedure