4.4 Example of How to Conduct the Site Survey
1.
Set the S-PS to CS Area Check mode and walk around the site survey Master CS to confirm the CS
coverage area. The recommended area is where the RSSI is more than 8 and the Error Rate is less than
02%. Then, locate the Slave CS within that area.
: Planned Location
Power
Source
Power
Source
Power
Source
Site Survey
Master Mode
Site Survey
Slave Mode
CS coverage area
LED:
Slow amber flashing
LED:
Slow green flashing
LED:
Red and green alternate flashing
c
CS Area Check using PS
CS
coverage area
Power
Source
Plotting a map with the RSSI
and Error Rate values makes
perfoming the site survey
easier. (You can check the map
when changing the location of
the CS.)
2.
Confirm whether the LED of the Slave CS is now flashing green slowly. If not, move the Slave CS to a
location where the LED is flashing green slowly.
After confirming the CS area using an S-PS, you need to confirm the radio signal
between the Master CS and Slave CS.
3.
Place the Master CS where the Slave CS was, and repeat steps 1 and 2 for all other locations.
Power
Source
LED:
Red and green alternate flashing
40
Installation Guide
4 Deployment Procedure