1.3.2 Characteristics
Terminal Equipment Loop Limit
•
PT: KX-DT300/KX-T7600 series DPT: 90
W
; all other DPTs/APTs:
40
W
•
SLT: 600
W
including set
•
Doorphone: 20
W
•
CS: 65
W
Minimum Leakage Resistance
15 000
W
minimum
Maximum Number of Extension
Instruments per Line
1.
for PT or SLT
2.
by Parallel or eXtra Device Port connection of an APT/DPT and
an SLT
3.
by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
W
maximum
Hookswitch Flash/Recall Timing
Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI2): 4.5 W per 1 line, 9 W per 2 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must
be grounded through the EIO4 card. For the connection diagram, refer
to "3.7.4 EIO4 Card (KX-TDA0164)". The PBX detects input from the
sensor when the signal is under 100
W
.
Paging Terminal Impedance
600
W
MOH (Music on Hold) Terminal
Impedance
10 000
W
Installation Manual
25
1.3.2 Characteristics
Содержание KX-NCP1000
Страница 42: ...42 Installation Manual 2 1 3 Activation Key File ...
Страница 52: ...Connector Type Pin Number Used for Mini Plug 2 4 IPCMPR 52 Installation Manual 3 2 5 Types of Connectors ...
Страница 134: ...134 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Страница 146: ...146 Installation Manual 5 1 5 Troubleshooting by Error Log ...
Страница 147: ...Section 6 Appendix Installation Manual 147 ...
Страница 151: ...Index Installation Manual 151 ...