49
Double Feed
1. Click
“Test”
on the main menu.
2. Click
“Double Feed”
on
the Test menu.
3. Set
“Send Level”
.
4. Open the ADF Door, and then place a sheet of clean white
paper between the Scanning Glass (F) and Scanning Glass
(B). Then close the ADF Door.
5. Click
“START”
to start the double feed sensor’s sensitivity
test.
6. Check whether the response level is within the specifications.
(See Remarks.)
7. Click
“STOP”
to finish this test.
8. Open the ADF Door, and then remove the white paper. Then
close the ADF Door.
9. Click
“Close”
to return to the Test menu.
—
Memory
1. Click
“Test”
on the main menu.
2. Click
“Memory”
on the Test menu.
3. Click
“START”
to start the Memory Read / Write Test.
4. Check the result.
5. Click
“Close”
to return to the Test menu.
—
For Error Code details, refer
to Sec.
Platen Motor
1.Click
“Test”
on the main menu.
2.Click
“Platen Motor”
on the Test menu.
3.Click
“START”
to rotate the Platen Motor.
(It rotates clockwise and counterclockwise alternately.)
4.Click
“STOP”
to finish the test.
5.Click
“Close”
to return to the Test menu.
—
Item
Operation
Default
Remarks
Содержание KV-S1027C
Страница 7: ...7 ...
Страница 9: ...9 3 Location of Controls and Components 3 1 Main Unit ...
Страница 10: ...10 ...
Страница 16: ...16 5 Section Views 5 1 Motor 5 2 Roller ...
Страница 17: ...17 5 3 Board and Sensor ...
Страница 31: ...31 7 3 8 Wiring of Upper Chassis ...
Страница 128: ...128 14 Exploded View and Replacement Parts List ...
Страница 133: ...133 14 3 Feed Tray Assembly 302 305 302 303 307 301 306 305 302 304 Feed Tray Assembly ...
Страница 180: ...180 15 Appendix The extract from an Operating Manual N K KVS1057C KVS1027C KVSL1066 KVSL1056 KVSL1055 KVSL1036 KVSL1035 ...
Страница 188: ...Index 74 8 Operating Manual Table of Contents ...
Страница 255: ...PNQX6995ZA DD0914HS0 Panasonic System Networks Co Ltd 2014 ...