background image

 

 

DS4600A QUICK GUIDE 

 

General View: 

Laser Safety: 

 

The scanner is classified as a Class 2 laser 
product according to EN 60825-1 regulations 
and as a Class II laser product according to 
CDRH regulations. 

For installation, use and maintenance it is not 
necessary to open the device. 

There is a safety device which allows the 
laser to be switched on only if the motor is 
rotating above the threshold for its correct 
scanning speed. 

The laser beam can be switched off through a 
software command (see also the WinHost 
Help On-Line). 

AVOID EXPOSURE 

LASER LIGHT IS EMITTED 

FROM THIS APERTURE 

CAUTION-CLASS 3B

LASER LIGHT 

WHEN OPEN 

AVOID 

EXPOSURE TO BEAM

      

 

Figure A 

Cable with 25-pin Connector

Laser Beam Output Window

Warning Label

Mounting Holes

Accessory Mounting Holes

Data TX LED

Good Read LED
Ready LED

External Trigger LED

Warning and Classification Labels

1

2
3
4
5

6

7

10

8
9

Keypad

11

Display

12

 
 

For further details on product installation, see the 
complete Installation Manual available on the WinHost 
CD included with this product.

 

DATALOGIC S.p.A. Via Candini, 2
40012 LIPPO DI CALDERARA (BO) ITALY

Model No.

Serial No.

Volt

Amp.

Manufactured

This product conforms to the applicable requirements of
21CFR1040 at the date of manufacture.

 

 

LASER LIGHT 

DO NOT STARE INTO BEAM 

CLASS 2 LASER PRODUCT 

MAXIMUM OUTPUT RADIATION  1 mW 
EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1 (2001) 

  

Warning and device class labels

 

 

Power Supply: 

-  This product is intended to be installed by Qualified 

Personnel only. 

- Models 

DS4600A-XXX0: 

This device is intended to be supplied by a UL Listed 
Direct Plug-in Power Unit marked “Class 2”, rated 10-30 
V minimum, 0.60 A. 
This device may also be supplied by a UL Listed Power 
Unit marked “Class 2” or LPS power source which 
supplies power directly to the scanner via the 25-pin 
connector. 

- Model 

DS4600A-2XX5: 

This device is intended to be supplied by a UL Listed 
Direct Plug-in Power Unit marked “Class 2”, rated 24 V 
minimum, 0.50 A. 
This device may also be supplied by a UL Listed Power 
Unit marked “Class 2” or LPS power source which 
supplies power directly to the scanner via the 25-pin 
connector. 

 

WEEE Compliance: 

 

The laser diode used in this device is classified 
as a class 3B laser product according to EN 
60825-1 regulations and as a Class IIIb laser 
product according to CDRH regulations. As it is 
not possible to apply a classification label on 
the laser diode used in this device, the 
following label is reproduced below. 

 

 

 

LASER LIGHT 

AVOID EXPOSURE TO BEAM 
CLASS 3B LASER PRODUCT 

MAX. OUTPUT RADIATION  30 mW 

EMITTED WAVE LENGTH  630~680 nm 

TO EN 60825-1 (2001) 

 

Laser diode class label 

Any violation of the optic parts in particular 
can cause radiation up to the maximum level 
of the laser diode (30 mW at 630 to 680 nm). 

 

DS4600A - 2XXX Models

 

6

7

8

9

10 

5

4

2

3

11 

12

2

DS4600A - 3XXX Models

Содержание Laser Barcode Reader DS4600A-2XX5

Страница 1: ...UTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630 680 nm TO EN 60825 1 2001 Warning and device class labels Power Supply This product is intended to be installed by Qualified Personnel only Models DS4600A...

Страница 2: ...93 Codabar Auxiliary Interface RS232 Pharmacode Baudrates 1200 to 115200 Inputs Headers and Up to four header and four External Trigger IN1 IN2 optocoupled NPN or PNP Terminators terminator character...

Страница 3: ...d through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female con...

Страница 4: ...t Output Connections Open Collector USER INTERFACE 8 11 12 22 DS4600A 25 pin Vext 40 Vdc max C E Output open collector connections VCE max 40 Vdc I max 40 mA continuous NPN NPN 5V DS4600A 25 pin USER...

Страница 5: ...rial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave...

Страница 6: ...0 300 400 mm 24 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 200X Medium Range CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angl...

Страница 7: ...240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 280 11 0 20 mm 8 mils 0 30 mm 12 mils DS4600A 22XX Short Range CONDITIONS Test Codes used Interleaved 2 5 and Code 39 PCS 0 90 Pitch angle 0 Ske...

Страница 8: ...0 550 mm 250 200 150 100 50 0 50 100 150 200 250 mm 20 22 0 25 mm 10 mils 0 30 mm 12 mils 0 50 mm 20 mils 8 10 DS4600A 2X2X Raster R2 CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0...

Страница 9: ...24 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 30XX Medium Range CONDITIONS Code Interleaved 2 5 and Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt an...

Страница 10: ...Pitch angle 0 Skew angle 15 Tilt angle 0 SW Resolution High Parameter selectable in WinHost 4 2 0 2 10 8 6 4 6 8 10 in 0 2 6 4 20 12 in 8 10 14 16 18 0 40 80 120 160 200 240 280 320 360 400 440 480 52...

Страница 11: ...8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D su...

Страница 12: ...ompatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in b...

Отзывы: