57
Configure the settings on the "SPECIAL SETUP" page
[SPECIAL SETUP]
Configure the settings relating to image quality can be configured on the "SPECIAL SETUP" page. The settings can
be configured on the "SPECIAL SETUP" page.
Refer to the operating instructions for descriptions of how to display the "SPECIAL SETUP" page using the buttons
on the camera. Refer to page 27 for how to display the "SPECIAL SETUP" page using a PC.
SPECIAL SETUP page
[CHROMA GAIN]
Adjust the chroma level (color density).
Color density will be incremented when the cursor is
moved to the "+" direction, and will be decremented
when the cursor is moved to the "–" direction.
Adjust the chroma gain while monitoring a vector color
scope or a color video monitor.
[AP GAIN]
Adjust the aperture level.
Images will be sharper when the cursor is moved to the
"+" direction, and will be softer when the cursor is
moved to the "–" direction. Adjust the aperture level
while monitoring a color video monitor.
Note:
Moire fringes (vertical interference pattern) may
appear when shooting figures such in a carpet or
drapes. In this case, move the cursor to the "–"
direction to alleviate this problem.
[PEDESTAL]
Adjust the brightness of images.
Images will be brighter when the cursor is moved to the
"+" direction, and will be darker when the cursor is
moved to the "–" direction. Adjust the pedestal while
monitoring an oscilloscope or a color video monitor.
[HUE]
Adjust the hue (color).
Adjust the hue (color) while monitoring a vector color
scope or a color video monitor.
Notes:
• The settings of "CHROIMA GAIN", "AP GAIN",
"PEDESTAL" and "HUE" can be reset to the default
settings by pressing the [Left] button and the [Right]
button for 2 seconds simultaneously.
• The hue (color) can be adjusted only for analog out-
put.
[PIX OFF]
Correct image defects (blemishes) such as scratches.
Up to 16 points can be corrected.
Refer to page 65 for descriptions of how to correct
defects.
[CAMERA RESET]
Reset the settings edited on the [Camera] tab to the
default settings.
Press simultaneously the [Left] button, [SET] button and
[Right] button for around 2 seconds after moving the
cursor onto "PUSH SW" of "CAMERA RESET". The set-
tings will be reset to the default settings.
**SPECIAL SETUP**
CHROMA GAIN ....
|
..160
AP GAIN .....
|
.193
PEDESTAL ...
|
...113
HUE ...
|
...129
- +
PIX OFF
CAMERA RESET PUSH SW
RET TOP END