Chapter 3 Function
3-2
3
3-1
Classification of Functions
In this system, all functions are classified into eight categories to ensure stable measurement
and various outputs.
Classification
Panel display
Function
Sensing Settings
Function settings for precise and stable measurement by
controlling the received light intensity of the sensor.
Data Processing
Settings
Function settings for processing measurement values.
Output Settings
Function settings related to output data processing.
Analog Settings
Function settings related to analog output processing.
Alarm Settings
Function settings related to alarm output processing.
COM Settings
Function settings related to communication.
System Settings
System settings such as "Initialization," "Save," and
communications settings.
Buffering Settings
*
Function settings related to buffering.
* This function is available to high-function type serial communication for which no
panel settings are possible.
3-2
Function List & Initial Values
Class
Function
Details
Initial value
Memory
change*
Ref.
page
Memory Change
Changes memory for saving the setting contents.
Default: M0
3-11
Sampling Cycle
Sets the sampling cycle for measurement.
Default: 500 µs
3-13
Shutter Time
Controls the receiving light intensity of the sensor
according to the amount of reflected light from
measurement targets.
Default: Auto
3-14
Se
nsi
ng set
ting
s
Light Intensity Monitor
Checks the current received light intensity.
- 3-15
Average Times
Sets the average number of times of moving average.
Default: 1024
3-16
Analysis Mode
Sets the analysis mode.
Default: Normal measurement
3-17
Span
Sets the measurement coefficient.
Default: 1.0000
3-17
Offset
Sets the measurement offset.
Default: 00000 mm
3-20
D
at
a P
roce
ss
ing
Se
tting
s
Zero-set OFF
Clears the zero-set state.
Default: OFF
3-19