Chapter 3 Function
3-35
3
Sensor No.
This function is used to set the number of each sensor head multi connected
to an RS-485 device.
Be sure to set each connecting sensor head number with no duplication.
Setting range
Function
Initial value
01 to 16
Set sensor numbers 01 through
16 in sequence.
●
Setting Procedure
1
Display the "COM Setting" screen while
in setting mode.
2
Press the [ENTER] key. The
"Terminating Resistor Selection" screen
will be displayed.
3
Press the [DOWN] key once. The
"Sensor No." screen will be displayed.
4
Press the [ENTER] key. The present
sensor number will be displayed.
5
Press the [UP]/[DOWN] key to change
the sensor number. (Example:
Changing the sensor number to 16.)
Supplemental remarks
Press the [UP]/[DOWN] keys together
for at least 2 seconds to move the set
value at high speed.
6
Press the [ENTER] key to determine the
sensor number.